D12312SVF20V Renesas Electronics America, D12312SVF20V Datasheet - Page 555

IC H8S/2312S MCU ROMLESS 100QFP

D12312SVF20V

Manufacturer Part Number
D12312SVF20V
Description
IC H8S/2312S MCU ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12312SVF20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
70
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12312SVF20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Serial Data Reception (Except Block Transfer Mode): Data reception in smart card mode uses
the same processing procedure as for the normal SCI. Figure 13.7 shows an example of the
transmission processing flow.
[1] Perform smart card interface mode initialization as described above in Initialization.
[2] Check that the ORER flag and PER flag in SSR are cleared to 0. If either is set, perform the
[3] Repeat steps [2] and [3] until it can be confirmed that the RDRF flag is set to 1.
[4] Read the receive data from RDR.
[5] When receiving data continuously, clear the RDRF flag to 0 and go back to step [2].
[6] To end reception, clear the RE bit to 0.
appropriate receive error handling, then clear both the ORER and the PER flag to 0.
No
No
RDRF flag in SSR to 0
Figure 13.7 Sample Reception Flowchart
Read RDR and clear
All data received?
Start of reception
Clear RE bit to 0
ORER = 0 and
Initialization
RDRF = 1?
PER = 0?
Start
Yes
Yes
Yes
No
Rev.7.00 Feb. 14, 2007 page 521 of 1108
Section 13 Smart Card Interface
Error handling
REJ09B0089-0700

Related parts for D12312SVF20V