HD64F3672FXV Renesas Electronics America, HD64F3672FXV Datasheet - Page 53

IC H8/3672 MCU FLASH 48LQFP

HD64F3672FXV

Manufacturer Part Number
HD64F3672FXV
Description
IC H8/3672 MCU FLASH 48LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheets

Specifications of HD64F3672FXV

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
26
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
48-LQFP
For Use With
R0K436079S000BE - KIT DEV FOR H8/36079 W/COMPILER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3672FXV
Manufacturer:
Renesas
Quantity:
1 000
Part Number:
HD64F3672FXV
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD64F3672FXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3672FXV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3672FXV
Manufacturer:
RENSAS-PB
Quantity:
595
Part Number:
HD64F3672FXV
Manufacturer:
RENESAS/PBF
Quantity:
52
2.5
The following describes the H8/300H CPU. In this LSI, the upper eight bits are ignored in the
generated 24-bit address, so the effective address is 16 bits.
2.5.1
The H8/300H CPU supports the eight addressing modes listed in table 2.10. Each instruction uses
a subset of these addressing modes. Addressing modes that can be used differ depending on the
instruction. For details, refer to appendix A.4, Combinations of Instructions and Addressing
Modes.
Arithmetic and logic instructions can use the register direct and immediate modes. Data transfer
instructions can use all addressing modes except program-counter relative and memory indirect.
Bit manipulation instructions use register direct, register indirect, or the absolute addressing mode
to specify an operand, and register direct (BSET, BCLR, BNOT, and BTST instructions) or
immediate (3-bit) addressing mode to specify a bit number in the operand.
Table 2.10 Addressing Modes
Register Direct—Rn
The register field of the instruction specifies an 8-, 16-, or 32-bit general register containing the
operand. R0H to R7H and R0L to R7L can be specified as 8-bit registers. R0 to R7 and E0 to E7
can be specified as 16-bit registers. ER0 to ER7 can be specified as 32-bit registers.
No.
1
2
3
4
5
6
7
8
Addressing Modes and Effective Address Calculation
Addressing Modes
Addressing Mode
Register direct
Register indirect
Register indirect with displacement
Register indirect with post-increment
Register indirect with pre-decrement
Absolute address
Immediate
Program-counter relative
Memory indirect
Symbol
Rn
@ERn
@(d:16,ERn)/@(d:24,ERn)
@ERn+
@–ERn
@aa:8/@aa:16/@aa:24
#xx:8/#xx:16/#xx:32
@(d:8,PC)/@(d:16,PC)
@@aa:8
Rev.4.00 Nov. 02, 2005 Page 27 of 304
REJ09B0143-0400
Section 2 CPU

Related parts for HD64F3672FXV