AT91SAM7A3-AU Atmel, AT91SAM7A3-AU Datasheet - Page 470

IC ARM7 MCU FLASH 256K 100LQFP

AT91SAM7A3-AU

Manufacturer Part Number
AT91SAM7A3-AU
Description
IC ARM7 MCU FLASH 256K 100LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheets

Specifications of AT91SAM7A3-AU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
60MHz
Connectivity
CAN, I²C, MMC, SPI, SSC, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
62
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LQFP
Controller Family/series
AT91SAM7xx
No. Of I/o's
62
Ram Memory Size
32KB
Cpu Speed
60MHz
No. Of Timers
3
Rohs Compliant
Yes
Package
100LQFP
Device Core
ARM7TDMI
Family Name
91S
Maximum Speed
60 MHz
Operating Supply Voltage
3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
62
Interface Type
CAN/SPI/I2S/TWI/USART/USB
On-chip Adc
2(8-chx10-bit)
Number Of Timers
3
Processor Series
AT91SAMx
Core
ARM7TDMI
Data Ram Size
32 KB
Maximum Clock Frequency
60 MHz
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM7A3-EK
Minimum Operating Temperature
- 40 C
Cpu Family
91S
Device Core Size
32b
Frequency (max)
60MHz
Total Internal Ram Size
32KB
# I/os (max)
62
Number Of Timers - General Purpose
3
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
100
Package Type
LQFP
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7A3-EK - KIT EVAL FOR AT91SAM7A3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7A3-AU
Manufacturer:
MXIC
Quantity:
1 001
Part Number:
AT91SAM7A3-AU
Manufacturer:
Atmel
Quantity:
730
Part Number:
AT91SAM7A3-AU
Manufacturer:
Atmel
Quantity:
10 000
0 = The MCI is not ready for new data transfer. Cleared at the end of the card response.
1 = The MCI is ready for new data transfer. Set when the busy state on the data line has ended. This corresponds to a free
internal data receive buffer of the card.
Refer to the MMC or SD Specification for more details concerning the busy behavior.
• ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in MCI_RCR or MCI_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in MCI_RCR or MCI_RNCR.
• ENDTX: End of TX Buffer
0 = The Transmit Counter Register has not reached 0 since the last write in MCI_TCR or MCI_TNCR.
1 = The Transmit Counter Register has reached 0 since the last write in MCI_TCR or MCI_TNCR.
Note:
• RXBUFF: RX Buffer Full
0 = MCI_RCR or MCI_RNCR has a value other than 0.
1 = Both MCI_RCR and MCI_RNCR have a value of 0.
• TXBUFE: TX Buffer Empty
0 = MCI_TCR or MCI_TNCR has a value other than 0.
1 = Both MCI_TCR and MCI_TNCR have a value of 0.
Note:
• RINDE: Response Index Error
0 = No error.
1 = A mismatch is detected between the command index sent and the response index received. Cleared when writing in
the MCI_CMDR.
• RDIRE: Response Direction Error
0 = No error.
1 = The direction bit from card to host in the response has not been detected.
• RCRCE: Response CRC Error
0 = No error.
1 = A CRC7 error has been detected in the response. Cleared when writing in the MCI_CMDR.
• RENDE: Response End Bit Error
0 = No error.
1 = The end bit of the response has not been detected. Cleared when writing in the MCI_CMDR.
• RTOE: Response Time-out Error
0 = No error.
1 = The response time-out set by MAXLAT in the MCI_CMDR has been exceeded. Cleared when writing in the
MCI_CMDR.
6042E–ATARM–14-Dec-06
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.
AT91SAM7A3 Preliminary
470

Related parts for AT91SAM7A3-AU