CV500BSC51 Omron, CV500BSC51 Datasheet - Page 21

no-image

CV500BSC51

Manufacturer Part Number
CV500BSC51
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500BSC51

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Specifications and Device Configuration
1-2-2
4
Name
Model number
Compatible PLCs
Unit type
Mounting location
Max. number of GP-IB Interface Units
Unit number setting range
GP-IB Interface Unit settings when editing the
I/O tables offline with the CX-Programmer
Transmission method
Communications method
Interface
Handshaking method
Functional specifications
(GP-IB interface functions)
Connection configurations
Transmission distance
Max. number of connected devices
GP-IB device address
Delimiters
Max. data transfer size
Max. number of connectors
Current consumption
Dimensions
Weight
Functional Specifications
Item
Note Max. Number of GP-IB Connectors
The GP-IB connector is equipped with a plug and a receptacle, so the con-
nectors can be stacked when necessary. Up to two GP-IB connectors can be
connected to a CS-series GP-IB Interface Unit when necessary.
One connector
connected
GPI01
SYSMAC CS-series GP-IB Interface Unit
CS1W-GPI01
CS-series PLCs
CS-series Special I/O Unit
CS-series CPU Rack or CS-series Expansion Rack
Up to 4 GP-IB Interface Units/CPU Unit
0 to 95
• Number of unit numbers occupied: 1
• Number of input words occupied: 5
• Number of output words occupied: 5
8-bit parallel data transfer
Half duplex
Conforms to IEEE-488-1978 (24-pin) standards
Three-line handshaking
Master mode: SH1, AH1, T6, TE0, L4, LE0, C1 to C4, and C28
Slave mode: SH1, AH1, T6, TE0, L4, LE0, SR1, RL0, PP0, DC1, and DT0
Star configuration or daisy-chain configuration
Limits on the length of cables in the system
(All three of these conditions must be satisfied simultaneously.)
• Total cable length
• Total cable length
• Length of a single cable
15 devices max. including the GP-IB Interface Unit
0 to 30
Select from the following: CR + LF, CR, LF, EOI, or user-set code.
512 bytes max. in a single reception or transmission
2 (See note.)
5 VDC, 330 mA
35
258 g max.
130
Up to two connectors
can be connected.
101 mm (W
GPI01
Number of devices in the system
20 m
H
4 m (for a 1:1 connection)
D)
Specification
2 m
Section 1-2