Z16F2811AL20SG Zilog, Z16F2811AL20SG Datasheet - Page 114

IC ZNEO MCU FLASH 128K 100LQFP

Z16F2811AL20SG

Manufacturer Part Number
Z16F2811AL20SG
Description
IC ZNEO MCU FLASH 128K 100LQFP
Manufacturer
Zilog
Series
Encore!® ZNEOr
Datasheets

Specifications of Z16F2811AL20SG

Core Processor
ZNEO
Core Size
16-Bit
Speed
20MHz
Connectivity
EBI/EMI, I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
76
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
100-LQFP
Processor Series
Z16F2x
Core
Zneo
Data Bus Width
16 bit
Data Ram Size
4 B
Interface Type
ESPI, I2C, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
76
Number Of Timers
4
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
Z16F2800100ZCOG
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 12 Channel
For Use With
770-1003 - ISP 4PORT FOR ZILOG ZNEO MCU269-4537 - DEV KIT FOR Z16F ZNEO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4533

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16F2811AL20SG
Manufacturer:
VISHAY
Quantity:
9 487
Part Number:
Z16F2811AL20SG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z16F2811AL20SG
Manufacturer:
ZILOG
Quantity:
20 000
PS022008-0810
Triggered One-Shot Mode Time-Out Period (s)
2. Write to the timer high and low byte registers to set the starting count value.
3. Write to the timer reload high and low byte registers to set the reload value.
4. Enable the timer interrupt, if required, and set the timer interrupt priority by writing to
5. When using the timer output function, configure the associated GPIO port pin for the
6. Write to the timer control 1 register to enable the timer. Counting does not start until
The timer period is calculated by the following equation (Start Value = 1):
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
timer reload high and low byte registers. After reaching the Reload value, the timer
generates an interrupt, the count value in the timer high and low byte registers is reset to
0001H
output pin changes state (from Low to High or High to Low) after timer Reload.
Follow the steps below to configure a timer for CONTINUOUS mode and initiate count:
1. Write to the timer control registers to:
2. Write to the timer high and low byte registers to set the starting count value (usually
3. Write to the timer reload high and low byte registers to set the Reload period.
4. Enable the timer interrupt, if required, and set the timer interrupt priority by writing to
5. When using the timer output function, configure the associated GPIO port pin for the
6. Write to the timer control 1 register to enable the timer and initiate counting.
The timer period is calculated by the following equation:
the relevant interrupt registers.
timer output alternate function.
the appropriate input transition occurs.
0001H). This only affects the first pass in CONTINUOUS mode. After the first timer
reload in CONTINUOUS mode, counting always begins at the reset value of
the relevant interrupt registers.
timer output alternate function.
and counting resumes. If the timer output alternate function is enabled, the timer
Disable the timer.
Configure the timer for CONTINUOUS mode.
Set the prescale value.
Set the initial output level (High or Low) through TPOL for the timer output
alternate function.
P R E L I M I N A R Y
=
----------------------------------------------------------------------------------------------------------
Reload Value Start Value + 1
System Clock Frequency (Hz)
Product Specification
ZNEO
Z16F Series
0001H
Prescale
Timers
.
99

Related parts for Z16F2811AL20SG