Z16F2811AL20SG Zilog, Z16F2811AL20SG Datasheet - Page 112

IC ZNEO MCU FLASH 128K 100LQFP

Z16F2811AL20SG

Manufacturer Part Number
Z16F2811AL20SG
Description
IC ZNEO MCU FLASH 128K 100LQFP
Manufacturer
Zilog
Series
Encore!® ZNEOr
Datasheets

Specifications of Z16F2811AL20SG

Core Processor
ZNEO
Core Size
16-Bit
Speed
20MHz
Connectivity
EBI/EMI, I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
76
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
100-LQFP
Processor Series
Z16F2x
Core
Zneo
Data Bus Width
16 bit
Data Ram Size
4 B
Interface Type
ESPI, I2C, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
76
Number Of Timers
4
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
Z16F2800100ZCOG
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 12 Channel
For Use With
770-1003 - ISP 4PORT FOR ZILOG ZNEO MCU269-4537 - DEV KIT FOR Z16F ZNEO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4533

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16F2811AL20SG
Manufacturer:
VISHAY
Quantity:
9 487
Part Number:
Z16F2811AL20SG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z16F2811AL20SG
Manufacturer:
ZILOG
Quantity:
20 000
Operation
PS022008-0810
Note:
Timer Operating Modes
The general-purpose timer is a 16-bit up-counter. In normal operation, the timer is
initialized to
reload high and low byte registers, then resets to
continues depending on the mode.
Minimum time-out delay (1 system clock) is set by loading the value
Timer Reload High and Low byte registers and setting the prescale value to 1.
Maximum time-out delay (2
the Timer Reload High and Low byte registers and setting the prescale value to 128. When
the timer reaches
If the reload register is set to a value less than the current counter value, the counter
continues counting until it reaches
continues to count until it reaches the reload value and it resets to
When T0IN0, T0IN1, and T0IN2 functions are enabled on the PB0, PB1, and PB2 pins,
each Timer0 input will have the same effect as the single Timer0 Input pin T0IN. For
example, if the Timer 0 is in Capture Mode, any transitions on any of the PB0, PB1, and
PB2 pins will cause a Capture.
The timers are configured to operate in the following modes:
ONE-SHOT Mode
In ONE-SHOT mode, the timer counts up to the 16-bit reload value stored in the Timer
Reload High and Low byte registers. The timer input is the system clock. When the timer
reaches the reload value, it generates an interrupt and the count value in the Timer High
and Low byte registers is reset to
counting.
If the timer output alternate function is enabled, the timer output pin changes state for one
system clock cycle (from Low to High then back to Low if TPOL = 0) at timer Reload. If
the timer output is required to make a permanent state change on ONE-SHOT timeout,
first set the TPOL bit in the timer control 1 register to the start value before beginning
ONE-SHOT mode. Then, after starting the timer, set TPOL to the opposite value.
Follow the steps below to configure a timer for ONE-SHOT mode and initiate the count:
1. Write to the timer control registers to:
Disable the timer.
Configure the timer for ONE-SHOT mode.
Set the prescale value.
0001H
FFFFH
. When the timer is enabled, it counts up to the value contained in the
, the timer rolls over to
P R E L I M I N A R Y
16
* 2
0001H
7
FFFFH
system clocks) is set by loading the value
. The timer is automatically disabled and stops
, and then resets to
0000H
0001H
.
. The counter either halts or
0000H
Product Specification
0001H
ZNEO
. Then the timer
0001H
.
Z16F Series
into the
0000H
Timers
into
97