HD6433935 Hitachi, HD6433935 Datasheet - Page 92

no-image

HD6433935

Manufacturer Part Number
HD6433935
Description
8-Bit MICROCONTROLLER
Manufacturer
Hitachi
Datasheet
3.4
3.4.1
When word data is accessed in the H8/3937 Series and H8/3937R Series, the least significant bit
of the address is regarded as 0. Access to the stack always takes place in word size, so the stack
pointer (SP: R7) should never indicate an odd address. Use PUSH Rn (MOV.W Rn, @–SP) or
POP Rn (MOV.W @SP+, Rn) to save or restore register values.
Setting an odd address in SP may cause a program to crash. An example is shown in figure 3-6.
When CCR contents are saved to the stack during interrupt exception handling or restored when
RTE is executed, this also takes place in word size. Both the upper and lower bytes of word data
are saved to the stack; on return, the even address contents are restored to CCR while the odd
address contents are ignored.
80
SP
SP set to H'FEFF
Notation:
PC
PC
R1L:
SP:
Application Notes
Notes on Stack Area Use
H
L
:
:
Upper byte of program counter
Lower byte of program counter
General register R1L
Stack pointer
Figure 3-6 Operation when Odd Address is Set in SP
BSR instruction
SP
Stack accessed beyond SP
PC
PC
H
L
MOV. B R1L, @–R7
SP
Contents of PC are lost
PC
R1L
L
H
H'FEFC
H'FEFD
H'FEFF