HD64F3670 RENESAS [Renesas Technology Corp], HD64F3670 Datasheet - Page 149

no-image

HD64F3670

Manufacturer Part Number
HD64F3670
Description
Hitachi Single-Chip Microcomputer
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3670FP
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3670FPV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
HD64F3670FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3670FXV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
HD64F3670FXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD64F3670FY
Quantity:
10
Part Number:
HD64F3670FYV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
HD64F3670FYV
Manufacturer:
Renesas
Quantity:
101
Part Number:
HD64F3670FYV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
TIM08W0A_000020020300
The timer W has a 16-bit timer having output compare and input capture functions. The timer W
can count external events and output pulses with an arbitrary duty cycle by compare match
between the timer counter and four general registers. Thus, it can be applied to various systems.
11.1
Table 11.1 summarizes the timer W functions, and figure 11.1 shows a block diagram of the timer
W.
Selection of five counter clock sources: four internal clocks ( , /2, /4, and /8) and an
external clock (external events can be counted)
Capability to process up to four pulse outputs or four pulse inputs
Four general registers:
Four selectable operating modes :
Any initial timer output value can be set
Five interrupt sources
Four compare match/input capture interrupts and an overflow interrupt.
Independently assignable output compare or input capture functions
Usable as two pairs of registers; one register of each pair operates as a buffer for the output
compare or input capture register
Waveform output by compare match
Selection of 0 output, 1 output, or toggle output
Input capture function
Rising edge, falling edge, or both edges
Counter clearing function
Counters can be cleared by compare match
PWM mode
Up to three-phase PWM output can be provided with desired duty ratio.
Features
Section 11 Timer W
Rev. 2.0, 03/02, page 125 of 298