m58lt256jsb STMicroelectronics, m58lt256jsb Datasheet - Page 25

no-image

m58lt256jsb

Manufacturer Part Number
m58lt256jsb
Description
256 Mbit 16 Mb 16, Multiple Bank, Multilevel, Burst 1.8 V Supply, Secure Flash Memories
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M58LT256JSB
Manufacturer:
ST
0
Part Number:
m58lt256jsb8ZA6
Manufacturer:
ST
0
Part Number:
m58lt256jsb8ZA6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
m58lt256jsb8ZA6F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
M58LT256JST, M58LT256JSB
4.10
4.10.1
Buffer Enhanced Factory Program command
The Buffer Enhanced Factory Program command has been specially developed to speed up
programming in manufacturing environments where the programming time is critical.
It is used to program one or more write buffer(s) of 32 words to a block. Once the device
enters Buffer Enhanced Factory Program mode, the write buffer can be reloaded any
number of times as long as the address remains within the same block. Only one block can
be programmed at a time.
If the block being programmed is protected, then the program operation aborts, the data in
the block is not changed, and the Status Register outputs the error.
The use of the Buffer Enhanced Factory Program command requires the following operating
conditions:
Dual operations are not supported during the Buffer Enhanced Factory Program operation
and the command cannot be suspended.
The Buffer Enhanced Factory Program command consists of three phases: the setup
phase, the program and verify phase, and the exit phase. Please refer to
commands
Setup phase
The Buffer Enhanced Factory Program command requires two bus write cycles to initiate the
command.
After the confirm command is issued, read operations output the contents of the Status
Register. The read Status Register command must not be issued or it is interpreted as data
to program.
The Status Register P/EC Bit SR7 should be read to check that the P/EC is ready to
proceed to the next phase.
If an error is detected, SR4 goes high (set to ‘1’) and the Buffer Enhanced Factory Program
operation is terminated. See
V
V
Ambient temperature T
The targeted block must be unprotected
The start address must be aligned with the start of a 32-word buffer boundary
The address must remain the start address throughout programming.
The first bus write cycle sets up the Buffer Enhanced Factory Program command.
The second bus write cycle confirms the command.
PP
DD
must be set to V
must be within operating range
for detailed information.
PPH
A
Section 5: Status Register
must be 30 °C ± 10 °C
for details on the error.
Command interface
Table 6: Factory
25/108

Related parts for m58lt256jsb