LM3S101-CRN20-XNPT Luminary Micro, Inc., LM3S101-CRN20-XNPT Datasheet - Page 134

no-image

LM3S101-CRN20-XNPT

Manufacturer Part Number
LM3S101-CRN20-XNPT
Description
Microcontroller
Manufacturer
Luminary Micro, Inc.
Datasheet
9.2.3.2
March 22, 2006
Table 9-1.
a. T
16-Bit Input Edge Count Mode
In Edge Count mode, the timer is configured as a down-counter capable of capturing three types
of events: rising edge, falling edge, or both. To place the timer in Edge Count mode, the TnCMR bit
of the GPTMTnMR register must be set to 0. The type of edge that the timer counts is determined
by the TnEVENT fields of the GPTMCTL register. During initialization, the Timern Match
(GPTMTnMATCHR) register is configured so that the difference between the value in the
GPTMTnILR register and the GPTMTnMATCHR register equals the number of edge events that
must be counted.
When software writes the TnEN bit in the GPTM Control (GPTMCTL) register, the timer is enabled
for event capture. Each input event on the CCP pin decrements the counter by 1 until the event
count matches GPTMTnMATCHR. When the counts match, the GPTM asserts the CnMRIS bit
(and the CnMMIS bit, if the interrupt is not masked). The counter is then reloaded using the value in
GPTMTnILR, and stopped since the GPTM automatically clears the TnEN bit in the GPTMCTL
register. Once the event count has been reached, all further events are ignored until TnEN is re-
enabled by software.
Figure 9-2 shows how input edge count mode works. In this case, the timer start value is set to
GPTMnILR=0x000A and the match value is set to GPTMnMATCHR=0x0006 so that 4 edge
events are counted. The counter is configured to detect both edges of the input signal.
Note that the last two edges are not counted since the timer automatically clears the TnEN bit after
the current count matches the value in the GPTMnMR register.
00000010
------------
11111100
11111110
11111111
c
Prescale
is the clock period.
16-Bit Timer With Prescaler Configurations
3
--
254
255
256
#Clock (T
c
)
a
Preliminary
3.9321
332.9229
334.2336
335.5443
Max Time
mS
mS
mS
mS
Units
LM3S101 Data Sheet
134

Related parts for LM3S101-CRN20-XNPT