TMP86xy12MG Toshiba, TMP86xy12MG Datasheet - Page 98

no-image

TMP86xy12MG

Manufacturer Part Number
TMP86xy12MG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP86xy12MG

Package
SSOP30
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
16
Ram Size
512
Driver Led
8
Driver Lcd
-
Spi/sio Channels
1
Uart/sio Channels
1
I2c/sio Channels
-
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
8
Da Converter Channels
-
Timer Counter 18-bit Channel
IGBT
Timer Counter 16-bit Channel
1
Timer Counter 8-bit Channel
2
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
24
Power Supply (v)
4.5 to 5.5
9.4.3 Configuring how the timer stops
9.4.4 One-time/continuous output mode
9.4.3.1 Counting stopped with the outputs initialized
9.4.3.2 Counting stopped with the outputs maintained
9.4.3.3 Counting stopped with the outputs initialized at the end of the period
9.4.4.1
9.4.4.2 Continuous output mode
Setting TC7ST to 0 causes the timer to stop with the specified output state according to the setting of STM.
the values specified with PPG1INI and PPG2INI.
maintained.
To restart the counter from the maintained state (STM = 01), set TC7ST to 1. The counter is restarted with
the initial output values, specified with PPG1INI and PPG2INI.
stops. If a stop trigger is detected before the end of the period, however, the counter stops immediately.
TC7CR1 and TC7CR2 must not be rewritten before the counter stops completely.
The CNTBF flag (TC7CR3<CNTBF>) can be read to determine whether the counter has stopped.
timer stops counting at the end of a period.
and the counter stops at the end of the period or when a stop trigger is detected, after which it waits for a
trigger again.
beginning in one-time output mode.
mode, the timer outputs specified waveforms continuously.
One-time output mode
When STM is set to 00, the counter stops immediately with the PPG1 and PPG2 outputs initialized to
When STM is set to 01, the counter stops immediately with the current PPG1 and PPG2 output states
When STM is set to 10, the counter continues counting until the end of the current period and then
Starting the timer (TC7ST = 1) with STM set to 10 specifies one-time output mode. In this mode, the
For a trigger start, the counter is stopped until a trigger is detected. A specified trigger restarts counting
For a command start, the counter is stopped until TC7ST is reset to 1.
TC7CR1 and TC7CR2 must not be rewritten before the counter stops completely.
The CNTBF flag (TC7CR3<CNTBF>) can be read to determine whether the counter has stopped.
TC7ST remains set to 1 after the counter is stopped.
When TC7ST is set to 1, setting STM to 10 clears the counter, which then restarts counting from the
Starting the timer (TC7ST = 1) with STM set to 00 or 01 specifies continuous output mode. In this
Page 87