PEF 20550 H V2.1 Infineon Technologies, PEF 20550 H V2.1 Datasheet - Page 196

no-image

PEF 20550 H V2.1

Manufacturer Part Number
PEF 20550 H V2.1
Description
IC INTERFACE CTRLR PCM MQFP80
Manufacturer
Infineon Technologies
Series
ELIC®r
Datasheet

Specifications of PEF 20550 H V2.1

Function
Line Card Controller
Interface
ISDN, PCM
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
15mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
80-SQFP
Includes
Change Detection, Power-Up Reset Generation
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEF20550HV2.1XT
PEF20550HV21XP
SP000007794
SP000007795
PEB 20550
PEF 20550
Application Hints
The Monitor/Feature Control handler can be adjusted to operate according to the
– IOM-1 protocol (up to 1 byte, no handshake), the
– IOM-2 protocol (any number of bytes, handshake using the MR and MX bits) and to
the
– SLD protocol (up to 16 bytes in subsequent frames without handshake)
The Monitor/Feature Control handler is a dedicated unit that communicates only with
one IOM or SLD channel at a time. An address register selects one out of 64 possible
MF channels. A 16 byte bidirectional FIFO (MFFIFO) provides intermediate storage for
the data to be sent or received. The message transfer over the MF channel is always
half-duplex, i.e. data can either be sent at a time or received at a time. It should be noted
that if the IOM-2 protocol is selected, the actual message length i.e. the number of bytes
to be sent or received is unlimited and is not restricted by the MFFIFO size!
If non handshake protocols (IOM-1 and SLD) are used, the ELIC must always be the
master of the MF communication. Example: the ELIC programs and reads back the
coefficients of a SICOFI (PEB 2060) device.
If the handshake protocol is used (IOM-2), a balanced MF communication is also
possible: since the MF handler cannot be pointed to all IOM-2 channels at the same time,
the ELIC has implemented a search function that looks for active monitor transmit
handshake (MX) bits on all upstream IOM-2 channels. If an active channel is found, the
address is stored and an interrupt is generated. The MF handler can then be pointed to
that particular channel and the message transfer can take place.
Example: the ELIC reads an EOC message out of an IECQ (PEB 2091) device.
The Control/Signaling handler can be adjusted to handle the following types of
channels:
• 4 bit C/I channel (IOM-1 and digital IOM-2)
• 6 bit C/I or Signaling channel (analog IOM-2)
• 8 bit Signaling channel (SLD)
Semiconductor Group
196
01.96

Related parts for PEF 20550 H V2.1