MCP2510-I/SO Microchip Technology, MCP2510-I/SO Datasheet - Page 43

IC CAN CONTRLER IND TEMP 18SOIC

MCP2510-I/SO

Manufacturer Part Number
MCP2510-I/SO
Description
IC CAN CONTRLER IND TEMP 18SOIC
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP2510-I/SO

Package / Case
18-SOIC (7.5mm Width)
Controller Type
CAN Interface
Interface
SPI
Voltage - Supply
3 V ~ 5.5 V
Current - Supply
10mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Supply Current (max)
10 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
DV251001 - KIT DEVELOPMENT CAN MCP2510
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP2510-I/SO
Quantity:
5 510
Part Number:
MCP2510-I/SO
Manufacturer:
MICROCHIP
Quantity:
8 000
Part Number:
MCP2510-I/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
MCP2510-I/SO
Quantity:
84
REGISTER 6-3:
© 2007 Microchip Technology Inc.
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
EFLG - ERROR FLAG REGISTER (ADDRESS: 2Dh)
bit 7
RX1OVR: Receive Buffer 1 Overflow Flag
- Set when a valid message is received for RXB1 and CANINTF.RX1IF = 1
- Must be reset by MCU
RX0OVR: Receive Buffer 0 Overflow Flag
- Set when a valid message is received for RXB0 and CANINTF.RX0IF = 1
- Must be reset by MCU
TXBO: Bus-Off Error Flag
- Bit set when TEC reaches 255
- Reset after a successful bus recovery sequence
TXEP: Transmit Error-Passive Flag
- Set when TEC is equal to or greater than 128
- Reset when TEC is less than 128
RXEP: Receive Error-Passive Flag
- Set when REC is equal to or greater than 128
- Reset when REC is less than 128
TXWAR: Transmit Error Warning Flag
- Set when TEC is equal to or greater than 96
- Reset when TEC is less than 96
RXWAR: Receive Error Warning Flag
- Set when REC is equal to or greater than 96
- Reset when REC is less than 96
EWARN: Error Warning Flag
- Set when TEC or REC is equal to or greater than 96 (TXWAR or RXWAR = 1)
-
Legend:
R = Readable bit
-n = Value at POR
RX1OVR
Reset when both REC and TEC are less than 96
R/W-0
RX0OVR
R/W-0
TXBO
R-0
W = Writable bit
’1’ = Bit is set
TXEP
R-0
RXEP
U = Unimplemented bit, read as ‘0’
’0’ = Bit is cleared
R-0
TXWAR
R-0
MCP2510
x = Bit is unknown
RXWAR
R-0
DS21291F-page 43
EWARN
R-0
bit 0

Related parts for MCP2510-I/SO