LAN9303-ABZJ Standard Microsystems (SMSC), LAN9303-ABZJ Datasheet - Page 85

no-image

LAN9303-ABZJ

Manufacturer Part Number
LAN9303-ABZJ
Description
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Specifications of LAN9303-ABZJ

Number Of Primary Switch Ports
3
Operating Supply Voltage (typ)
3.3V
Fiber Support
No
Power Supply Type
Analog
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Operating Temperature Classification
Commercial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9303-ABZJ
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
SMSC LAN9303/LAN9303i
For clarity, the following details the incoming un-tag instruction. As described in
Support," on page
VLAN table. The entry in the VLAN table is either the VLAN from the received packet or the ingress
port’s default VID.
When a received packet is non-tagged, a new VLAN tag is added if two conditions are met. First,
the Insert Tag bit for the egress port in the
(BM_EGRSS_PORT_TYPE)
tag instruction associated with the ingress port’s default VID, must be cleared. The VLAN tag that
is added will have a VID taken from either the ingress or egress port’s default VID. The priority of
the VLAN tag is either the priority calculated on ingress or the egress port’s default. The choice of
ingress or egress is determined by the egress port’s VID/Priority Select bit in the
Egress Port Type Register
When a received packet is priority-tagged, either the tag is removed or it is modified.
If the un-tag bit, for the egress port, from the un-tag instruction associated with the ingress port’s
default VID is set, then the tag is removed.
Otherwise, the tag is modified. The VID of the new VLAN tag is changed to either the ingress or
egress port’s default VID. If the Change Priority bit in the
(BM_EGRSS_PORT_TYPE)
is also changed. The priority of the VLAN tag is either the priority calculated on ingress or the
egress port’s default. The choice of ingress or egress is determined by the egress port’s
VID/Priority Select bit.
When a received packet is normal-tagged, either the tag is removed, modified, or passed
unchanged.
If the un-tag bit, for the egress port, from the un-tag instruction associated with the VID in the
received packet is set, then the tag is removed.
Else, if the Change Tag bit in the
(BM_EGRSS_PORT_TYPE)
Else, if both the Change VLAN ID and the Change Priority bits in the
Type Register (BM_EGRSS_PORT_TYPE)
untouched.
Otherwise, the tag is modified. If the Change VLAN ID bit for the egress port is set, the VID of the
new VLAN tag is changed to either the ingress or egress port’s default VID. If the Change Priority
bit for the egress port is set, the Priority field of the new VLAN tag is changed to either the priority
calculated on ingress or the egress port’s default. The choice of ingress or egress is determined
by the egress port’s VID / Priority Select bit.
When a packet is received special-tagged from a CPU port, the special tag is removed.
74, the un-tag instruction is the three un-tag bits from the applicable entry in the
(BM_EGRSS_PORT_TYPE).
must be set. Second, the un-tag bit, for the egress port, from the un-
for the egress port is set, then the Priority field of the new VLAN tag
for the egress port is clear, the packet passes untouched.
DATASHEET
Buffer Manager Egress Port Type Register
85
Buffer Manager Egress Port Type Register
for the egress port are clear, the packet passes
Buffer Manager Egress Port Type Register
Buffer Manager Egress Port
Section 6.4.4, "VLAN
Revision 1.4 (07-07-10)
Buffer Manager

Related parts for LAN9303-ABZJ