D12332VFC20V Renesas Electronics America, D12332VFC20V Datasheet - Page 674

IC H8S/2332 MCU ROMLESS 144QFP

D12332VFC20V

Manufacturer Part Number
D12332VFC20V
Description
IC H8S/2332 MCU ROMLESS 144QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12332VFC20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
106
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12332VFC20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Rev.4.00 Sep. 07, 2007 Page 642 of 1210
REJ09B0245-0400
No
No
No
Figure 14.12 Sample Multiprocessor Serial Reception Flowchart
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
Read MPIE bit in SCR
FER ∨ ORER = 1?
FER ∨ ORER = 1?
All data received?
Start of reception
This station's ID?
Initialization
RDRF = 1?
RDRF = 1?
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
[4]
[3]
[1]
[2]
Error handling
(Continued on
next page)
[5]
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.

Related parts for D12332VFC20V