MC9S08SH16MTG Freescale Semiconductor, MC9S08SH16MTG Datasheet - Page 157

no-image

MC9S08SH16MTG

Manufacturer Part Number
MC9S08SH16MTG
Description
MCU 8BIT 16K FLASH 16-TSSOP
Manufacturer
Freescale Semiconductor
Series
HCS08r
Datasheet

Specifications of MC9S08SH16MTG

Core Processor
HCS08
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, LIN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
13
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
16-TSSOP
Core
S08
Processor Series
MC9S08Sxx
Data Bus Width
8 bit
Maximum Clock Frequency
40 MHz
Data Ram Size
1 KB
On-chip Adc
Yes
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
8
Height
1.05 mm
Interface Type
SCI, SPI, I2C
Length
5 mm
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Width
4.4 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
10.3.4
Freescale Semiconductor
Reset
BUSY
ARBL
RXAK
Field
IAAS
SRW
IICIF
TCF
7
6
5
4
2
1
0
W
R
IIC Status Register (IICS)
TCF
Transfer Complete Flag. This bit is set on the completion of a byte transfer. This bit is only valid during or
immediately following a transfer to the IIC module or from the IIC module.The TCF bit is cleared by reading the
IICD register in receive mode or writing to the IICD in transmit mode.
0 Transfer in progress
1 Transfer complete
Addressed as a Slave. The IAAS bit is set when the calling address matches the programmed slave address
or when the GCAEN bit is set and a general call is received. Writing the IICC register clears this bit.
0 Not addressed
1 Addressed as a slave
Bus Busy. The BUSY bit indicates the status of the bus regardless of slave or master mode. The BUSY bit is
set when a start signal is detected and cleared when a stop signal is detected.
0 Bus is idle
1 Bus is busy
Arbitration Lost. This bit is set by hardware when the arbitration procedure is lost. The ARBL bit must be cleared
by software by writing a 1 to it.
0 Standard bus operation
1 Loss of arbitration
Slave Read/Write. When addressed as a slave, the SRW bit indicates the value of the R/W command bit of the
calling address sent to the master.
0 Slave receive, master writing to slave
1 Slave transmit, master reading from slave
IIC Interrupt Flag. The IICIF bit is set when an interrupt is pending. This bit must be cleared by software, by
writing a 1 to it in the interrupt routine. One of the following events can set the IICIF bit:
0 No interrupt pending
1 Interrupt pending
Receive Acknowledge. When the RXAK bit is low, it indicates an acknowledge signal has been received after
the completion of one byte of data transmission on the bus. If the RXAK bit is high it means that no acknowledge
signal is detected.
0 Acknowledge received
1 No acknowledge received
1
7
• One byte transfer completes
• Match of slave address to calling address
• Arbitration lost
= Unimplemented or Reserved
IAAS
0
6
Figure 10-6. IIC Status Register (IICS)
MC9S08SH32 Series Data Sheet, Rev. 2
Table 10-7. IICS Field Descriptions
BUSY
0
5
PRELIMINARY
ARBL
0
4
Description
3
0
0
Chapter 10 Inter-Integrated Circuit (S08IICV2)
SRW
0
2
IICIF
0
1
RXAK
0
0
157