R5F61668RN50FPV Renesas Electronics America, R5F61668RN50FPV Datasheet - Page 158

IC H8SX/1668 MCU FLASH 144LQFP

R5F61668RN50FPV

Manufacturer Part Number
R5F61668RN50FPV
Description
IC H8SX/1668 MCU FLASH 144LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of R5F61668RN50FPV

Core Processor
H8SX
Core Size
16/32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
92
Program Memory Size
1MB (1M x 8)
Program Memory Type
FLASH
Ram Size
56K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
For Use With
R0K561668S000BE - KIT STARTER FOR H8SX/1668R0K561664S001BE - KIT STARTER FOR H8SX/1651HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F61668RN50FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 6 Exception Handling
The interrupt exception handling is as follows:
1. The contents of PC, CCR, and EXR are saved in the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. An exception handling vector table address corresponding to the interrupt source is generated,
6.7
There are three instructions that cause exception handling: trap instruction, sleep instruction, and
illegal instruction.
6.7.1
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state. The trap
instruction exception handling is as follows:
1. The contents of PC, CCR, and EXR are saved in the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. An exception handling vector table address corresponding to the vector number specified in
A start address is read from the vector table corresponding to a vector number from 0 to 3, as
specified in the instruction code.
Table 6.8 shows the state of CCR and EXR after execution of trap instruction exception handling.
Table 6.8
[Legend]
1:
0:
:
Rev. 2.00 Sep. 24, 2008 Page 124 of 1468
REJ09B0412-0200
Interrupt Control Mode
0
2
the start address of the exception service routine is loaded from the vector table to PC, and
program execution starts from that address.
the TRAPA instruction is generated, the start address of the exception service routine is loaded
from the vector table to PC, and program execution starts from that address.
Set to 1
Cleared to 0
Retains the previous value.
Instruction Exception Handling
Trap Instruction
Status of CCR and EXR after Trap Instruction Exception Handling
I
1
1
CCR
UI
0
T
EXR
I2 to I0