tmp89fm42 TOSHIBA Semiconductor CORPORATION, tmp89fm42 Datasheet - Page 358

no-image

tmp89fm42

Manufacturer Part Number
tmp89fm42
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp89fm42AUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42LUG
Manufacturer:
ST
Quantity:
500
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
745
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
1 000
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
Manufacturer:
PROCONN
Quantity:
3 705
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/PBF
Quantity:
29
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
0
Company:
Part Number:
tmp89fm42UG
Quantity:
15 795
Company:
Part Number:
tmp89fm42UG
Quantity:
2 400
Part Number:
tmp89fm42UG(C
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(C,JZ)
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(CZHZ)
0
Part Number:
tmp89fm42UG(JZ)
Manufacturer:
Toshiba
Quantity:
10 000
22.8 Operation Commands
22. Serial PROM Mode
RA002
Table 22-11 Transfer Formats of the Flash Memory SUM Output Command
22.8.5 Flash memory SUM output command (operation command: 0x90)
BOOT
ROM
Note 1: "0x** u 3" means that the device goes into an idle state after transmitting 3 bytes of 0x**. For further information, refer to
Note 2: For information on checksums, refer to "22.10 Checksum (SUM)".
Note 3: If data to be included in the checksum are all 0xFF, the 7th byte becomes 0xAA. If any one piece of data to be included in
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
9th byte
10th byte
Transfer byte
Table 22-11 shows the transfer formats of the flash memory SUM output command.
Table 22-18.
the checksum is other than 0xFF, the 7th byte becomes 0x55.
Matching data 1 (0x86 or 0x30)
-
Matching data 2 (0x79 or 0xCF)
-
Operation command data (0x90)
-
(Wait for the next operation command data)
-
-
-
Transfer data from the external controller to
TMP89FM42
Page 344
Automatic adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
- (Automatic baud rate adjustment)
OK: Echo back data (0x86 or 0x30)
Error: No data transmitted
-
OK: Echo back data (0x79 or 0xCF)
Error: No data transmitted
-
OK: No data transmitted (0x90)
Error: 0xA1 u 3, 0xA3 u 3, 0x63 u 3 (note 1)
0x55 : -
0xAA: All data are 0xFF.
OK: Checksum (high) (note 2)
Error: No data transmitted
OK: Checksum (low) (note 2)
Error: No data transmitted
-
Transfer data from TMP89FM42 to the
external controller
TMP89FM42