MCF5280CVM66 Freescale Semiconductor, MCF5280CVM66 Datasheet - Page 587

IC MPU 32BIT COLDF 256-MAPBGA

MCF5280CVM66

Manufacturer Part Number
MCF5280CVM66
Description
IC MPU 32BIT COLDF 256-MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5280CVM66

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
66MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
142
Program Memory Type
ROMless
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Controller Family/series
ColdFire
No. Of I/o's
150
Program Memory Size
2KB
Ram Memory Size
64KB
Cpu Speed
66.67MHz
Embedded Interface Type
CAN, I2C, SPI, UART
No. Of Pwm Channels
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5280CVM66
Manufacturer:
FREESCAL
Quantity:
151
Part Number:
MCF5280CVM66
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCF5280CVM66J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCF5280CVM66L
Manufacturer:
FREESCAL
Quantity:
151
bit should be cleared before another scan of queue 1 is initiated during the next open gate. The start of
queue 1 is always the first CCW in the CCW table.
Because the gate level is only sampled after each conversion during queue execution, closing the gate for
a period less than a conversion time interval does not guarantee the closure will be captured.
28.8.6.4 Interval Timer Single-Scan Mode
Both queues can use the periodic/interval timer in a single-scan queue operating mode. The timer interval
can range from 2
selected and the single-scan enable bit is set in QACR1 or QACR2, the timer begins counting. When the
time interval elapses, an internal trigger event is generated to start the queue and the QADC begins
execution with the first CCW.
The QADC automatically performs the conversions in the queue until a pause or an end-of-queue
condition is encountered. When a pause occurs, queue execution stops until the timer interval elapses
again, and queue execution continues. When queue execution reaches an end-of-queue situation, the
single-scan enable bit is cleared. Set the single-scan enable bit again to allow another scan of the queue to
be initiated by the interval timer.
The interval timer generates a trigger event whenever the time interval elapses. The trigger event may
cause queue execution to continue following a pause or may be considered a trigger overrun. Once queue
execution is completed, the single-scan enable bit must be set again to allow the timer to count again.
Normally, only one queue is enabled for interval timer single-scan mode, and the timer will reset at the
end-of-queue. However, if both queues are enabled for either single-scan or continuous interval timer
mode, the end-of-queue condition will not reset the timer while the other queue is active. In this case, the
timer will reset when both queues have reached end-of-queue. See
Timer
The interval timer single-scan mode can be used in applications that need coherent results. For example:
28.8.7
A continuous-scan queue operating mode is used to execute multiple passes through a sequence of
conversions defined by a queue. By programming the MQ1 field in QACR1 or the MQ2 field in QACR2,
these modes can be selected:
When a queue is programmed for a continuous-scan mode, the single-scan enable bit in the queue control
register does not have any meaning or effect. As soon as the queue operating mode is programmed, the
selected trigger event can initiate queue execution.
Freescale Semiconductor
for a definition of interval timer reset conditions.
When it is necessary that all samples are guaranteed to be taken during the same scan of the analog
signals
When the interrupt rate in the periodic timer continuous-scan mode would be too high
In sensitive battery applications, where the interval timer single-scan mode uses less power than
the software-initiated continuous-scan mode
Software-initiated continuous-scan mode
Externally triggered continuous-scan mode
Externally gated continuous-scan mode
Periodic timer continuous-scan mode
Continuous-Scan Modes
Queue 2 cannot be programmed for externally gated continuous-scan mode.
7
to 2
17
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
QCLK cycles in binary multiples. When the interval timer single-scan mode is
NOTE
Queued Analog-to-Digital Converter (QADC)
Section 28.8.9, “Periodic/Interval
28-49

Related parts for MCF5280CVM66