C8051F336DK Silicon Laboratories Inc, C8051F336DK Datasheet - Page 103

DEV KIT FOR C8051F336

C8051F336DK

Manufacturer Part Number
C8051F336DK
Description
DEV KIT FOR C8051F336
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F336DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F33x
Interface Type
USB, UART
Operating Supply Voltage
7 V to 15 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F336
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1430
SFR Definition 17.1. VDM0CN: V
SFR Address = 0xFF
17.3. External Reset
The external RST pin provides a means for external circuitry to force the device into a reset state. Assert-
ing an active-low signal on the RST pin generates a reset; an external pullup and/or decoupling of the RST
pin may be necessary to avoid erroneous noise-induced resets. See
tics” on page 27
external reset.
17.4. Missing Clock Detector Reset
The Missing Clock Detector (MCD) is a one-shot circuit that is triggered by the system clock. If the system
clock remains high or low for more than 100 µs, the one-shot will time out and generate a reset. After a
MCD reset, the MCDRSF flag (RSTSRC.2) will read ‘1’, signifying the MCD as the reset source; otherwise,
this bit reads ‘0’. Writing a ‘1’ to the MCDRSF bit enables the Missing Clock Detector; writing a ‘0’ disables
it. The state of the RST pin is unaffected by this reset.
Name
Reset
Bit
5:0
Type
7
6
Bit
VDDSTAT
UNUSED
VDMEN
VDMEN
Name
Varies
R/W
7
for complete RST pin specifications. The PINRSF flag (RSTSRC.0) is set on exit from an
VDDSTAT
V
This bit turns the V
tem resets until it is also selected as a reset source in register RSTSRC (SFR Def-
inition 17.2). Selecting the V
may generate a system reset. In systems where this reset would be undesirable, a
delay should be introduced between enabling the V
reset source.
0: V
1: V
V
This bit indicates the current power supply status (V
0: V
1: V
Unused. Read = 000000b; Write = Don’t care.
Varies
DD
DD
R
6
DD
DD
DD
DD
Monitor Enable.
Status.
Monitor Disabled.
Monitor Enabled.
is at or below the V
is above the V
R
5
0
DD
DD
DD
monitor circuit on/off. The V
Monitor Control
monitor threshold.
DD
Rev.1.0
R
4
0
DD
monitor threshold.
monitor as a reset source before it has stabilized
Function
R
3
0
Section “6. Electrical Characteris-
C8051F336/7/8/9
DD
R
2
0
DD
DD
Monitor cannot generate sys-
Monitor and selecting it as a
Monitor output).
R
1
0
R
0
0
103