ATTINY20-EK1 Atmel, ATTINY20-EK1 Datasheet - Page 143

no-image

ATTINY20-EK1

Manufacturer Part Number
ATTINY20-EK1
Description
KIT EVAL TOUCH ATTINY20
Manufacturer
Atmel
Datasheet

Specifications of ATTINY20-EK1

Sensor Type
*
Sensing Range
*
Interface
*
Sensitivity
*
Voltage - Supply
*
Embedded
*
Utilized Ic / Part
*
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
TinyAVR
Kit Contents
Board
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny20
Tool / Board Applications
Microcontroller
Rohs Compliant
Yes
Tool Type
Development Kit
Cpu Core
AVR 8
Data Bus Width
8 bit
Processor To Be Evaluated
ATtiny20
Interface Type
Touch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
17.3.8
17.3.9
8235B–AVR–04/11
Arbitration
Synchronization
In the case where the slave is stretching the clock the master will be forced into a wait-state until
the slave is ready and vice versa.
A master can only start a bus transaction if it has detected that the bus is idle. As the TWI bus is
a multi master bus, it is possible that two devices initiate a transaction at the same time. This
results in multiple masters owning the bus simultaneously. This is solved using an arbitration
scheme where the master loses control of the bus if it is not able to transmit a high level on the
SDA line. The masters who lose arbitration must then wait until the bus becomes idle (i.e. wait
for a STOP condition) before attempting to reacquire bus ownership. Slave devices are not
involved in the arbitration procedure.
Figure 17-9. TWI Arbitration
Figure 17-9
devices are able to issue a START condition, but DEVICE1 loses arbitration when attempting to
transmit a high level (bit 5) while DEVICE2 is transmitting a low level.
Arbitration between a repeated START condition and a data bit, a STOP condition and a data
bit, or a repeated START condition and STOP condition are not allowed and will require special
handling by software.
A clock synchronization algorithm is necessary for solving situations where more than one mas-
ter is trying to control the SCL line at the same time. The algorithm is based on the same
principles used for clock stretching previously described.
two masters are competing for the control over the bus clock. The SCL line is the wired-AND
result of the two masters clock outputs.
shows an example where two TWI masters are contending for bus ownership. Both
Figure 17-10
shows an example where
ATtiny20