ATTINY20-EK1 Atmel, ATTINY20-EK1 Datasheet - Page 126

no-image

ATTINY20-EK1

Manufacturer Part Number
ATTINY20-EK1
Description
KIT EVAL TOUCH ATTINY20
Manufacturer
Atmel
Datasheet

Specifications of ATTINY20-EK1

Sensor Type
*
Sensing Range
*
Interface
*
Sensitivity
*
Voltage - Supply
*
Embedded
*
Utilized Ic / Part
*
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
TinyAVR
Kit Contents
Board
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny20
Tool / Board Applications
Microcontroller
Rohs Compliant
Yes
Tool Type
Development Kit
Cpu Core
AVR 8
Data Bus Width
8 bit
Processor To Be Evaluated
ATtiny20
Interface Type
Touch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
15.13.3
126
ATtiny20
ADCSRA – ADC Control and Status Register A
• Bit 7 – ADEN: ADC Enable
Writing this bit to one enables the ADC. By writing it to zero, the ADC is turned off. Turning the
ADC off while a conversion is in progress, will terminate this conversion.
• Bit 6 – ADSC: ADC Start Conversion
In Single Conversion mode, write this bit to one to start each conversion. In Free Running mode,
write this bit to one to start the first conversion. The first conversion after ADSC has been written
after the ADC has been enabled, or if ADSC is written at the same time as the ADC is enabled,
will take 25 ADC clock cycles instead of the normal 13. This first conversion performs initializa-
tion of the ADC.
ADSC will read as one as long as a conversion is in progress. When the conversion is complete,
it returns to zero. Writing zero to this bit has no effect.
• Bit 5 – ADATE: ADC Auto Trigger Enable
When this bit is written to one, Auto Triggering of the ADC is enabled. The ADC will start a con-
version on a positive edge of the selected trigger signal. The trigger source is selected by setting
the ADC Trigger Select bits, ADTS in ADCSRB.
• Bit 4 – ADIF: ADC Interrupt Flag
This bit is set when an ADC conversion completes and the data registers are updated. The ADC
Conversion Complete Interrupt is executed if the ADIE bit and the I-bit in SREG are set. ADIF is
cleared by hardware when executing the corresponding interrupt handling vector. Alternatively,
ADIF is cleared by writing a logical one to the flag.
Beware that if doing a Read-Modify-Write on ADCSRA, a pending interrupt can be disabled.
• Bit 3 – ADIE: ADC Interrupt Enable
When this bit is written to one and the I-bit in SREG is set, the ADC Conversion Complete Inter-
rupt is activated.
Bit
0x12
Read/Write
Initial Value
ADEN
R/W
7
0
ADSC
R/W
6
0
ADATE
R/W
5
0
ADIF
R/W
4
0
ADIE
R/W
3
0
ADPS2
R/W
2
0
ADPS1
R/W
1
0
ADPS0
R/W
0
0
8235B–AVR–04/11
ADCSRA