EVB9303 SMSC, EVB9303 Datasheet - Page 155

EVALUATION BOARD FOR LAN9303

EVB9303

Manufacturer Part Number
EVB9303
Description
EVALUATION BOARD FOR LAN9303
Manufacturer
SMSC
Datasheets

Specifications of EVB9303

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9303
Primary Attributes
3 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
Full Duplex and HP Auto-MDIX Support, 10BASE-T and 100BASE-TX
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1095
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
SMSC LAN9303/LAN9303i
BITS
0
Port 2 Full-Duplex Manual Flow Control Select (MANUAL_FC_2)
This bit toggles flow control selection between manual and auto-negotiation.
0: If auto-negotiation is enabled, the auto-negotiation function
determines the flow control of switch Port 2 (RX_FC_2 and TX_FC_2
values ignored). If auto-negotiation is disabled, the RX_FC_2 and
TX_FC_2 values are used.
1: TX_FC_2 and RX_FC_2 bits determine the flow control of switch Port
2 when in full-duplex mode
Note 13.8 The default value of this field is determined by the
Note 13.9 The default value of this bit is determined by multiple strap settings. The strap values are
Note 13.10 The default value of this field is determined by the
Note 13.11 The default value of this field is determined by the
strap values are loaded during reset and can be re-written by the EEPROM Loader. Once
the EEPROM Loader re-writes the values, this register is updated with the new values.
See
loaded during reset and can be re-written by the EEPROM Loader. Once the EEPROM
Loader re-writes the values, this register is updated with the new values. Refer to
6.2.3, "Flow Control Enable Logic," on page 62
strap values are loaded during reset and can be re-written by the EEPROM Loader. Once
the EEPROM Loader re-writes the values, this register is updated with the new values.
See
The strap values are loaded during reset and can be re-written by the EEPROM Loader.
Once the EEPROM Loader re-writes the values, this register is updated with the new
values. See
Section 4.2.4, "Configuration Straps," on page 45
Section 4.2.4, "Configuration Straps," on page 45
Section 4.2.4, "Configuration Straps," on page 45
DESCRIPTION
DATASHEET
155
for additional information.
BP_EN_strap_2
FD_FC_strap_2
manual_FC_strap_2
for more information.
for more information.
for more information.
TYPE
R/W
configuration strap. The
configuration strap. The
Revision 1.4 (07-07-10)
configuration strap.
Note 13.11
DEFAULT
Section

Related parts for EVB9303