AT25DL081-MHN-T Adesto Technologies, AT25DL081-MHN-T Datasheet - Page 31

no-image

AT25DL081-MHN-T

Manufacturer Part Number
AT25DL081-MHN-T
Description
Flash 8M 1.65-1.95V 100Mhz Serial Flash
Manufacturer
Adesto Technologies
Datasheet

Specifications of AT25DL081-MHN-T

Rohs
yes
Data Bus Width
8 bit
Memory Type
Flash
Memory Size
8 Mbit
Architecture
Flexible, Uniform Erase
Timing Type
Synchronous
Interface Type
SPI
Supply Voltage - Max
1.95 V
Supply Voltage - Min
1.65 V
Maximum Operating Current
20 mA
Operating Temperature
- 40 C to + 85 C
Mounting Style
SMD/SMT
Package / Case
UDFN-8
10.3
Read Sector Lockdown Registers
The Sector Lockdown Registers can be read to determine the current lockdown status of each physical 64KB sector. To
read the Sector Lockdown Register for a particular 64KB sector, the CS pin must first be asserted and then the opcode
35h must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the
64KB sector must be clocked in. After the address bytes have been clocked in, data will be output on the SO pin during
every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of
the appropriate Sector Lockdown Register.
At clock frequencies above f
above f
appropriate Sector Lockdown Register.
Table 10-2. Read Sector Lockdown Register – Output Data
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can
be deasserted at any time and does not require that a full byte of data be read.
Figure 10-3. Read Sector Lockdown Register
SCK
Output Data
SO
CS
SI
00h
FFh
CLK
, at least two bytes of data must be clocked out from the device in order to determine the correct status of the
MSB
High-impedance
0
0
Sector Lockdown Register Value
Sector Lockdown Register value is 0 (sector is not locked down).
Sector Lockdown Register value is 1 (sector is permanently locked down).
0
1
1
2
Opcode
1
3
CLK
0
4
, the first byte of data output will not be valid. Therefore, if operating at clock frequencies
1
5
0
6
1
7
MSB
A
8
A
9
A
Address Bits A23-A0
10 11
A
A
12
A
A
29 30
A
A
31 32
MSB
X
X
33
X
34
Don't Care
X
35
X
36
X
37 38
AT25DL081 [DATASHEET]
X
X
39
MSB
D
40
D
41
D
42 43
8732E–DFLASH–1/2013
Data Byte
D
D
44
D
45
D
46
D
47 48