SH3100IMTR SEMTECH [Semtech Corporation], SH3100IMTR Datasheet - Page 57

no-image

SH3100IMTR

Manufacturer Part Number
SH3100IMTR
Description
Supervisory IC with I2C Interface and PWM
Manufacturer
SEMTECH [Semtech Corporation]
Datasheet
System Reset – Programmable VDD Threshold (VBO)
The SH3100 has two dedicated supervisory functions
that manage the reset of the microcontroller, a low VDD
monitor (Brownout Detector) with programmable thresh-
old (VBO) and a Watchdog Timer with programmable time-
out. Both functions are integrated with the Clock Manage-
ment System to provide a more complete solution than
with standalone components. The SH3100 NRST output
pin is active Low with strong drive to the active state and
weak drive to the inactive state. This eliminates the need
for an external pull-up and allows the NRST pin to be con-
nected in common with other reset sources in a wired-OR
confi guration.
During power-up, the NRST pin is guaranteed to be cor-
rectly asserted by the time VDD reaches 1V. It then stays
asserted until VDD exceeds the programmed VDD thresh-
old (VBO) + hysteresis, at which point the SH3100 enters
the power up routine with the appropriate sequencing of
clock start and NRST negation as determined by the pro-
grammable reset duration setting. Flags in the register
map indicate the cause of reset to the microcontroller.
Once powered up, the SH3100 continuously monitors
VDD and generates a system reset on the NRST pin if VDD
drops below VBO. VBO is set by a 7-bit control code to be
between 1.7V and 4V with 24mV resolution. When VDD
drops below VBO, this is defi ned as a brownout event, and
if VBAK is present, the chip switches to battery backup
mode to maintain register contents and RTC operation
at very low current consumption. If VBAK is not present,
backup mode operation continues to run from VDD until
VDD drops below 1V.
© 2006 Semtech Corp.
POWER MANAGEMENT
Functional Descriptions
Parameter
VBO for Min code (000 0000)
VBO for Max code (101 1110)
VDD Hysteresis
VDD falling to NRST asserted delay
VBO resolution
New VBO settling time
(continued)
Symbol
VBOmax
VBOmin
Vhys
Tvbo
Vres
Td
57
The default VBO setting is loaded from nonvolatile memo-
ry on power up, but once the chip has come out of reset,
it may be changed to any other value using an I
or it can be permanently protected from any changes by
setting the VBO lock fl ag or the write protect fl ag. To avoid
the system jumping in and out of reset for noisy VDD levels
near VBO, there is hysteresis on the reset function. When
VDD is falling, NRST asserts at VBO. When VDD is rising,
NRST negates at VBO plus the hysteresis (Vhys). There is
also internal fi ltering on the VDD comparator which is set
to allow rapid detection of a collapsing VDD while reject-
ing VDD noise spikes of less than a certain duration and
amplitude as shown by the diagram to follow:
1.65
3.95
than 100μs) then it is advisable to add an external 100 nF
decoupling capacitor on VREG to maintain register contents
while the chip changes over to battery backup mode.
Min
Note: If VDD is likely to collapse very quickly to GND (Less
25
20
Typ
1.7
24
4
Max
1.75
4.05
100
28
5
4
www.semtech.com
Units
mV
mV
ms
μs
V
V
SH3100
2
C access,

Related parts for SH3100IMTR