Z8F082A28100KIT ZILOG [Zilog, Inc.], Z8F082A28100KIT Datasheet - Page 177

no-image

Z8F082A28100KIT

Manufacturer Part Number
Z8F082A28100KIT
Description
Z8 Encore XP-R F08xA Series with eXtended Peripherals
Manufacturer
ZILOG [Zilog, Inc.]
Datasheet
PS024705-0405
BITS
FIELD
RESET
R/W
OCD Status Register
DBG
through a normal Power-On Reset sequence with the exception that the On-Chip Debug-
ger is not reset. This bit is automatically cleared to 0 at the end of reset.
0 = No effect.
1 = Reset the Flash Read Protect Option Bit device.
The OCD Status register reports status information about the current state of the debugger
and the system.
DBG—Debug Status
0 = NORMAL mode
1 = DEBUG mode
HALT—HALT Mode
0 = Not in HALT mode
1 = In HALT mode
FRPENB—Flash Read Protect Option Bit Enable
0 = FRP bit enabled, that allows disabling of many OCD commands
1 = FRP bit has no effect
Reserved—Must be 0.
R
7
0
HALT
R
0
6
Table 100. OCD Status Register (OCDSTAT)
FRPENB
R
5
0
P R E L I M I N A R Y
R
4
0
R
0
3
Z8 Encore! XP
Reserved
R
2
0
Product Specification
R
0
1
®
On-Chip Debugger
F08xA Series
R
0
0
159