LPC47N237-MD SMSC [SMSC Corporation], LPC47N237-MD Datasheet - Page 46

no-image

LPC47N237-MD

Manufacturer Part Number
LPC47N237-MD
Description
3.3V I/O CONTROLLER FOR PORT REPLICATORS AND DOCKING STATIONS
Manufacturer
SMSC [SMSC Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
45
Part Number:
LPC47N237-MD
Manufacturer:
FUJI
Quantity:
575
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
1 000
9.1.3
Revision 0.3 (10-26-04)
The means of clearing the TIMEOUT bit is controlled by the TIMEOUT_SELECT bit as follows. The
TIMEOUT_SELECT bit is located at bit 2 of CR21.
The TIMEOUT bit is cleared on PCI_RESET regardless of the state of the TIMEOUT_SELECT bit.
BITS 1, 2 - are not implemented as register bits, during a read of the Printer Status Register these bits are
a low level.
BIT 3 nERR - nERROR
The level on the nERROR input is read by the CPU as bit 3 of the Printer Status Register. A logic 0 means
an error has been detected; a logic 1 means no error has been detected.
BIT 4 SLCT - PRINTER SELECTED STATUS
The level on the SLCT input is read by the CPU as bit 4 of the Printer Status Register. A logic 1 means
the printer is on line; a logic 0 means it is not selected.
BIT 5 PE - PAPER END
The level on the PE input is read by the CPU as bit 5 of the Printer Status Register. A logic 1 indicates a
paper end; a logic 0 indicates the presence of paper.
BIT 6 nACK - nACKNOWLEDGE
The level on the nACK input is read by the CPU as bit 6 of the Printer Status Register. A logic 0 means
that the printer has received a character and can now accept another. A logic 1 means that it is still
processing the last character or has not received the data.
BIT 7 nBUSY - nBUSY
The complement of the level on the BUSY input is read by the CPU as bit 7 of the Printer Status Register.
A logic 0 in this bit means that the printer is busy and cannot accept a new character. A logic 1 means that
it is ready to accept the next character.
Control Port
ADDRESS OFFSET = 02H
The Control Port is located at an offset of '02H' from the base address. The Control Register is initialized
by the RESET input, bits 0 to 5 only being affected; bits 6 and 7 are hard wired low.
BIT 0 STROBE - STROBE
This bit is inverted and output onto the nSTROBE output.
BIT 1 AUTOFD - AUTOFEED
This bit is inverted and output onto the nAUTOFD output. A logic 1 causes the printer to generate a line
feed after each line is printed. A logic 0 means no autofeed.
If the TIMEOUT_SELECT bit is cleared (‘0’), the TIMEOUT bit is cleared on the trailing edge of the
read of the EPP Status Register (default)
If the TIMEOUT_SELECT bit is set (‘1’), the TIMEOUT bit is cleared on a write of ‘1’ to the TIMEOUT
bit.
DATASHEET
Page 46
3.3v I/O Controller for Port Replicators and Docking Stations
SMSC DS – LPC47N237

Related parts for LPC47N237-MD