FDC37B787QF SMSC [SMSC Corporation], FDC37B787QF Datasheet - Page 81

no-image

FDC37B787QF

Manufacturer Part Number
FDC37B787QF
Description
Super I/O Controller with ACPI Support, Real Time Clock and Consumer IR
Manufacturer
SMSC [SMSC Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37B787QFP
Quantity:
1 000
FIFO POLLED MODE OPERATION
With FCR bit 0 = "1" resetting IER bits 0, 1, 2 or 3
or all to zero puts the UART in the FIFO Polled
Mode of operation.
XMITTER are controlled separately, either one or
both can be in the polled mode of operation. In this
mode, the user's program will check RCVR and
XMITTER status via the LSR. LSR definitions for
the FIFO Polled Mode are as follows:
-
-
Bit 0=1 as long as there is one byte in the
RCVR FIFO.
Bits 1 to 4 specify which error(s) have
occurred. Character error status is handled
Since the RCVR and
82
-
-
-
There is no trigger level reached or timeout
condition indicated in the FIFO Polled Mode,
however, the RCVR and XMIT FIFOs are still fully
capable of holding characters.
the same way as when in the interrupt
mode, the IIR is not affected since EIR bit
2=0.
Bit 5 indicates when the XMIT FIFO is empty.
Bit 6 indicates that both the XMIT FIFO and
shift register are empty.
Bit 7 indicates whether there are any errors in
the RCVR FIFO.