PIC18F1230 MICROCHIP [Microchip Technology], PIC18F1230 Datasheet - Page 42

no-image

PIC18F1230

Manufacturer Part Number
PIC18F1230
Description
18/20/28-Pin, Enhanced Flash Microcontrollers with nanoWatt Technology, High-Performance PWM and A/D
Manufacturer
MICROCHIP [Microchip Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F1230-E/SS
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
PIC18F1230-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F1230-I/P
Manufacturer:
MICROCHIP
Quantity:
5
Part Number:
PIC18F1230-I/P
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F1230-I/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F1230-I/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F1230T-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
PIC18F1230/1330
4.6
Most registers are unaffected by a Reset. Their status
is unknown on POR and unchanged by all other
Resets. The other registers are forced to a “Reset
state” depending on the type of Reset that occurred.
Most registers are not affected by a WDT wake-up,
since this is viewed as the resumption of normal oper-
ation. Status bits from the RCON register, RI, TO, PD,
POR and BOR, are set or cleared differently in different
Reset situations, as indicated in Table 4-3. These bits
are used in software to determine the nature of the
Reset.
TABLE 4-3:
DS39758B-page 40
Power-on Reset
RESET Instruction
Brown-out Reset
MCLR during Power-Managed
Run Modes
MCLR during Power-Managed
Idle Modes and Sleep Mode
WDT Time-out during Full Power
or Power-Managed Run Mode
MCLR during Full Power
Execution
Stack Full Reset (STVREN = 1)
Stack Underflow Reset
(STVREN = 1)
Stack Underflow Error (not an
actual Reset, STVREN = 0)
WDT Time-out during
Power-Managed Idle or
Sleep Modes
Interrupt Exit from
Power-Managed Modes
Legend: u = unchanged
Note 1:
2:
Reset State of Registers
When the wake-up is due to an interrupt and the GIEH or GIEL bit is set, the PC is loaded with the
interrupt vector (008h or 0018h).
Reset state is ‘1’ for POR and unchanged for all other Resets when software BOR is enabled
(BOREN1:BOREN0 Configuration bits = 01 and SBOREN = 1); otherwise, the Reset state is ‘0’.
Condition
STATUS BITS, THEIR SIGNIFICANCE AND THE INITIALIZATION CONDITION
FOR RCON REGISTER
Program
PC + 2
Counter
PC + 2
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
(1)
Advance Information
SBOREN
u
u
u
u
u
u
u
u
u
u
u
1
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
RCON Register
RI
Table 4-4 describes the Reset states for all of the
Special Function Registers. These are categorized by
Power-on and Brown-out Resets, Master Clear and
WDT Resets and WDT wake-ups.
1
0
1
u
u
u
u
u
u
u
u
u
TO
1
u
1
1
1
0
u
u
u
u
0
u
PD
1
u
1
u
0
u
u
u
u
u
0
0
POR BOR STKFUL
0
u
u
u
u
u
u
u
u
u
u
u
© 2006 Microchip Technology Inc.
0
u
0
u
u
u
u
u
u
u
u
u
STKPTR Register
0
u
u
u
u
u
u
1
u
u
u
u
STKUNF
0
u
u
u
u
u
u
u
1
1
u
u

Related parts for PIC18F1230