MC68020 Motorola, MC68020 Datasheet - Page 146

no-image

MC68020

Manufacturer Part Number
MC68020
Description
(MC68020 / MC68EC020) MICROPROCESSORS USERS MANUAL
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68020/BZAJC
Quantity:
3
Part Number:
MC68020CEH16E
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68020CEH25
Manufacturer:
XILINX
Quantity:
101
Part Number:
MC68020CEH25E
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68020CFC16E
Manufacturer:
MOT
Quantity:
190
Part Number:
MC68020CFC16E
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
MC68020CFC20E
Manufacturer:
FREESCALE
Quantity:
101
Part Number:
MC68020CFC25
Manufacturer:
FREESCALE
Quantity:
101
Part Number:
MC68020CRC25E
Manufacturer:
AD
Quantity:
423
Part Number:
MC68020EH16E
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68020EH20E
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68020FC16E
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
ENTRY
TEMP
(SP) +
READ FORMAT WORD
SR
TEMP
SP
SP + 6
OTHERWISE
INVALID FORMAT WORD
FORMAT CODE = $1
(THROWAWAY FRAME)
OTHERWISE
TAKE FORMAT
ERROR EXCEPTION
FORMAT CODE = $0 (FOUR-WORD FRAME)
OTHERWISE
PC
(SP) +
OTHER FORMATS
SP
SP + 6
SR
TEMP
EXIT
Figure 6-7. RTE Instruction for Throwaway Four-Word Frame
For the coprocessor midinstruction stack frame, the processor reads the SR, PC,
instruction address, internal register values, and the evaluated effective address from the
stack, restores these values to the corresponding internal registers, and increments the
stack pointer by 20. The processor then reads from the response register of the
coprocessor that initiated the exception to determine the next operation to be performed.
Refer to Section 7 Coprocessor Interface Description for details of coprocessor-related
exceptions.
For both the short and long bus fault stack frames, the processor first checks the format
value on the stack for validity. In addition, for the long stack frame, the processor
compares the version number in the stack with its own version number. The version
number is located in the most significant nibble (bits 15–12) of the word at location SP +
$36 in the long stack frame. This validity check is required in a multiprocessor system to
ensure that the data is properly interpreted by the RTE instruction. The RTE instruction
also reads from both ends of the stack frame to make sure it is accessible. If the frame is
invalid or inaccessible, the processor takes a format error or a bus error exception,
respectively. Otherwise, the processor reads the entire frame into the proper internal
registers, deallocates the stack, and resumes normal processing. Once the processor
begins to load the frame to restore its internal state, the assertion of the BERR signal
MOTOROLA
M68020 USER’S MANUAL
6- 21

Related parts for MC68020