si4330 Silicon Laboratories, si4330 Datasheet - Page 47

no-image

si4330

Manufacturer Part Number
si4330
Description
Si4330 Ism Receiver
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si4330-A0-FM
Manufacturer:
SILICON
Quantity:
740
Part Number:
si4330-A0-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
si4330-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
si4330-B1-FM
Quantity:
75
Part Number:
si4330-B1-FM-02T
Manufacturer:
SILICON
Quantity:
112
Part Number:
si4330-B1-FMR
Manufacturer:
HIROSE
Quantity:
3 200
Part Number:
si4330-B1-FMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
si4330BDY-T1-E3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4330BDY-T1-GE3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4330DY-T1-E3
Manufacturer:
VISHAY
Quantity:
464
Part Number:
si4330DY-T1-E3
Manufacturer:
VISHAY
Quantity:
30 000
Company:
Part Number:
si4330DY-T1-E3
Quantity:
70 000
8.3. General Purpose ADC
An 8-bit SAR ADC is integrated onto the chip for general purpose use, as well as for digitizing the temperature
sensor reading. “Register 0Fh. ADC Configuration,” on page 86 must be configured depending on the use of the
GP ADC before use. The architecture of the ADC is demonstrated in Figure 18. First the input of the ADC must be
selected by setting the ADCSEL[2:0] depending on the use of the ADC. For instance, if the ADC is going to be
used to read out the internal temperature sensor, then ADCSEL[2:0] should be set to 000. Next, the input reference
voltage to the ADC must be chosen. By default, the ADC uses the bandgap voltage as a reference so the input
range of the ADC is from 0–1.02 V with an LSB resolution of 4 mV (1.02/255). Changing the ADC reference will
change the LSB resolution accordingly.
Every time the ADC conversion is desired, the ADCStart bit in “Register 0Fh. ADC Configuration,” on page 86 must
be set to 1. This is a self clearing bit that will be cleared at the end of the conversion cycle of the ADC. The
conversion time for the ADC is 350 us. After the 350 us or when the ADCstart/busy bit is cleared, then the ADC
value may be read out of "Register 11h. ADC Value". Setting the "Register 10h. ADC Sensor Amplifier Offset", ADC
Sensor Amplifier Offset is only necessary when the ADC is configured to used as a Bridge Sensor as described in
the following section.
Add R/W
0F
10
11
R/W
R/W
R
ADC Sensor Amplifier Offset
Function/Description
ADC Configuration
ADC Value
GPIO0
GPIO1
GPIO2
TS
V
BG
(1.2V)
ADCSEL<2:0>
Figure 18. General Purpose ADC Architecture
Diff. MUX
adcstart/adcbusy
adc[7]
OTR<3:0>
D7
V
V
BAT
BAT
Diff. Amp.
/ 3
/ 2
GAIN<1:0>
adcsel[2] adcsel[1] adcsel[0]
Preliminary Rev 0.2
adc[6]
D6
ADCSEL<2:0>
Input MUX
REFSEL<1:0>
adc[5]
Ref MUX
D5
adc[4]
D4
Vin
Vref
adcoffs[3]
adcref[1]
0-1020mV / 0-255
adc[3]
8-bit ADC
D3
adcoffs[2]
adcref[0]
adc[2]
D2
VMEAS<7:0>
adcgain[1] adcgain[0]
adcoffs[1]
adc[1]
D1
adcoffs[0]
adc[0]
Si4330
D0
POR Def.
00h
00h
47