ATmega1281R231 Atmel Corporation, ATmega1281R231 Datasheet - Page 243

no-image

ATmega1281R231

Manufacturer Part Number
ATmega1281R231
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATmega1281R231

Flash (kbytes)
128 Kbytes
Max. Operating Frequency
16 MHz
Max I/o Pins
54
Spi
3
Twi (i2c)
1
Uart
2
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Crypto Engine
AES
Sram (kbytes)
8
Eeprom (bytes)
4096
Operating Voltage (vcc)
1.8 to 3.6
Timers
6
Frequency Band
2.4 GHz
Max Data Rate (mb/s)
2
Antenna Diversity
Yes
External Pa Control
Yes
Power Output (dbm)
3
Receiver Sensitivity (dbm)
-101
Receive Current Consumption (ma)
13.2
Transmit Current Consumption (ma)
14.4
Link Budget (dbm)
104
24.3.3
2549N–AVR–05/11
Address Packet Format
Figure 24-3. START, REPEATED START and STOP conditions
All address packets transmitted on the TWI bus are 9 bits long, consisting of 7 address bits, one
READ/WRITE control bit and an acknowledge bit. If the READ/WRITE bit is set, a read opera-
tion is to be performed, otherwise a write operation should be performed. When a Slave
recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL
(ACK) cycle. If the addressed Slave is busy, or for some other reason can not service the Mas-
ter’s request, the SDA line should be left high in the ACK clock cycle. The Master can then
transmit a STOP condition, or a REPEATED START condition to initiate a new transmission. An
address packet consisting of a slave address and a READ or a WRITE bit is called SLA+R or
SLA+W, respectively.
The MSB of the address byte is transmitted first. Slave addresses can freely be allocated by the
designer, but the address 0000 000 is reserved for a general call.
When a general call is issued, all slaves should respond by pulling the SDA line low in the ACK
cycle. A general call is used when a Master wishes to transmit the same message to several
slaves in the system. When the general call address followed by a Write bit is transmitted on the
bus, all slaves set up to acknowledge the general call will pull the SDA line low in the ack cycle.
The following data packets will then be received by all the slaves that acknowledged the general
call. Note that transmitting the general call address followed by a Read bit is meaningless, as
this would cause contention if several slaves started transmitting different data.
All addresses of the format 1111 xxx should be reserved for future purposes.
Figure 24-4. Address Packet Format
SDA
SCL
SDA
SCL
START
START
Addr MSB
1
ATmega640/1280/1281/2560/2561
STOP
2
START
Addr LSB
7
REPEATED START
R/W
8
ACK
9
STOP
243