TXC-06101AILQ Transwitch Corporation, TXC-06101AILQ Datasheet - Page 174

no-image

TXC-06101AILQ

Manufacturer Part Number
TXC-06101AILQ
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-06101AILQ

Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Package Type
PQFP
Rad Hardened
No
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TXC-06101AILQ
Manufacturer:
ATMEL
Quantity:
100
Company:
Part Number:
TXC-06101AILQ A
Quantity:
32
Part Number:
TXC-06101AILQ-A
Manufacturer:
TRANSWITCH
Quantity:
20 000
Tx F1 Selection
Controls TXF1EXT (CR14; 1FE[H], Bit 4), TRF1(CR9; 1F9[H], Bit 7), and OA are used for F1 Selection. The
source selection is shown below where: & = the logical "AND" function, + = the logical "OR" function, and =
represents a control state.
Tx D1-D3 Selection
D1-D3 Byte selection is controlled by TRSD (CR8; 1F8[H], Bit 7) and TXSDEXT (CR14; 1FE[H], Bit 3) The
source selection is shown below where: & = the logical "AND" function, + = the logical "OR" function, and =
represents a control state.
In the OW/APS Application, the external source for the Bytes will be the Tx Section DCC Port. In the All TOH
Application, the external source will be either the Tx Section DCC Port or the Tx TOH Port, as controlled by OA
and SDCCEN (CR17; 1DD[H], Bit 7).
Tx H1-H3 Selection
The sources for the H1 and H2 Bytes may be either the Tx Terminal Port or the calculated values. The H3 Byte
Sources are either the Tx Terminal Port or the Insert Location. If transmit re-timing is disabled, the Tx Terminal
Locations are used for H1, H2 and H3. When transmit re-timing is enabled, the calculated H1 and H2 values,
and the H3 Insert Location value, are used. The H3 value taken from the Insert Location will be overwritten by
SPE data when a Pointer Decrement is performed. The source selection is shown below where: & = the logical
"AND" function, + = the logical "OR" function, and = represents a control state.
SPE-only Mode
not selected
& TRF1 = "0"
SPE-only Mode
not selected
& TRSD = "0"
Tx Terminal Port
Tx Terminal Port
Proprietary TranSwitch Corporation Information for use Solely by its Customers
SPE-only Mode not selected
& C1J1EN = "0"
& TXRTM = "0"
& TCLK = "0"
Tx Terminal Port
SPE-only Mode selected
& TXF1EXT = "0"
+
SPE-only Mode selected
& OA = "1"
+
TRF1 = "1"
& TXF1EXT = "0"
+
TRF1 = "1"
& OA = "1"
SPE-only Mode selected
& TXSDEXT = "0"
+
TRSD = "1"
& TXSDEXT = "0"
- 174 of 196 -
DATA SHEET
µPro
µPro
SPE-only Mode selected
+ C1J1EN = "1"
+ TXRTM = "1"
+TCLK = "1"
Insert Location - Internal
Insert Location
Insert Location
SPE-only Mode selected
& TXF1EXT = "1"
& OA = "0"
+
TRF1 = "1"
& TXF1EXT = "1"
& OA = "0"
SPE-only Mode selected
& TXSDEXT = "1"
+
TRSD = "1"
& TXSDEXT = "1"
External
External
TXC-06101
Ed. 3, April 2001
TXC-06101-MB
PHAST-1