RN-XV Roving Networks Inc, RN-XV Datasheet - Page 9

no-image

RN-XV

Manufacturer Part Number
RN-XV
Description
MODULE 802.11B/G 2.4GHZ
Manufacturer
Roving Networks Inc
Series
-r
Datasheets

Specifications of RN-XV

Frequency
2.4GHz
Data Rate - Maximum
54Mbps
Modulation Or Protocol
802.11b/g
Applications
General Purpose
Power - Output
12dBm
Sensitivity
-83dBm
Voltage - Supply
3 V ~ 3.7 V
Current - Receiving
40mA
Current - Transmitting
180mA
Data Interface
PCB, Through Hole
Memory Size
-
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
740-1044
RN-XV-W
RN-XVEE
XVEE
4. WiFly Command Reference
Commands begin with a keyword, and have optional additional parameters, generally space delimited.
Commands and options are case sensitive. Hex input data can be upper or lower case. String text data, such
as SSID is also case sensitive.
The first command is fully decoded and must be complete. Other command parameters can be shorted by
using only the first character.
For example,
Numbers can be entered as either decimal, (like 115200 above) or HEX. To enter HEX, use 0x<value>.
For example, the HEX value FF would be entered as 0xFF.
Commands fall into 5 general categories:
NOTE: You must save any changes made or the module will load the previous settings upon reboot or
power up. Configuration is saved using the save command.
When the system boots, all configuration data is loaded into RAM variables from the file called “config”.
The set commands actually only modify the RAM copy of variables in the system. In general, the IP,
4.1. Command Syntax
4.2. Command Organization
set uart baudrate 115200 is valid,
set uart b 115200 is also valid,
set u b 115200
s uart baudrate 115200 is NOT valid.
www.rovingnetworks.com
SET COMMANDS
GET COMMANDS
STATUS COMMANDS
ACTION COMMANDS
FILE IO COMMANDS
809 University Avenue
is also valid, however,
Los Gatos, CA 95032
Take effect immediately, permanently (when save command is issued).
Retrieve the permanently stored information for display to user.
See what is going on with the interface, IP status, etc.
Perform action such as scan, connect, disconnect, etc.
Upgrade, load and save configuration, delete files, etc.
~ 9 ~
Tel (408) 395-6539
• info@RovingNetworks.com
WiFly-RN-UM
WiFly GSX/EZX
5/4/2011

Related parts for RN-XV