RN-XV Roving Networks Inc, RN-XV Datasheet - Page 11

no-image

RN-XV

Manufacturer Part Number
RN-XV
Description
MODULE 802.11B/G 2.4GHZ
Manufacturer
Roving Networks Inc
Series
-r
Datasheets

Specifications of RN-XV

Frequency
2.4GHz
Data Rate - Maximum
54Mbps
Modulation Or Protocol
802.11b/g
Applications
General Purpose
Power - Output
12dBm
Sensitivity
-83dBm
Voltage - Supply
3 V ~ 3.7 V
Current - Receiving
40mA
Current - Transmitting
180mA
Data Interface
PCB, Through Hole
Memory Size
-
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
740-1044
RN-XV-W
RN-XVEE
XVEE
5.
These commands begin with “set”. There are 6 major categories.
Adhoc
Broadcast
COMM
DNS
FTP
IP
Option
Sys
Time
UART
WLAN
set adhoc beacon <ms>
set adhoc probe <num>
set broadcast address <addr> sets the address to which the UDP hello/heartbeat message is sent. The
set broadcast interval <value> sets the interval at which the hello/heartbeat UDP message is sent.
set broadcast port <port>
SET Commands
5.1. Adhoc Parameters
5.2. Broadcast Parameters
www.rovingnetworks.com
809 University Avenue
controls the adhoc parameters
controls the broadcast hello/heartbeat UDP message
communication and data transfer, timers, matching characters
DNS host and domain
FTP host address and login information
IP settings
optional and not frequently used parameters
system settings such as sleep and wake timers
timer server settings
serial port settings such as baudrate and parity
wireless interface settings, such as ssid, chan, and security options
Los Gatos, CA 95032
sets the adhoc beacon interval in milliseconds. Default is 100.
sets the adhoc probe timeout in seconds. This is the number of seconds
waiting for probe responses before declaring, “ADHOC is lost” and
disabling the network interface. Default is 60.
default address is 255.255.255.255
Interval is specified in seconds. The value is a mask that is compared to a
free running seconds counter. For example if interval = 0x7, a packet will
be sent every 8 seconds. The minimum interval value is 1 (every 2
seconds) and max value is 0xff (every 256 seconds). Setting the interval
value to zero disables sending UDP broadcast messages. Default interval
is 7.
sets the port number to which the UDP hello/heartbeat message is sent.
Default port is 55555.
~ 11 ~
Tel (408) 395-6539
• info@RovingNetworks.com
WiFly-RN-UM
WiFly GSX/EZX
5/4/2011

Related parts for RN-XV