Unit Settings and Replacement Precautions
Special I/O Units
Online Replacement of I/O Units, Special I/O Units, and CPU Bus Units
Analog Input Units
Analog Output
Units
Analog I/O Unit
Process I/O Units
Customizable
Counter Units
High-speed
Counter Units (2 or
4 axes)
Name and model
CS1W-AD041
CS1W-AD041-V1
CS1W-AD081
CS1W-AD081-V1
CS1W-DA041
CS1W-DA08V
CS1W-DA08C
CS1W-MAD44
CS1W-PTS01-V1
CS1W-PTS02/03
CS1W-PTW01
CS1W-PD01
CS1W-PMV01/02
CS1W-PTR01/02
CS1W-PPS01
CS1W-HIO01-V1
CS1W-HCP22-V1
CS1W-HCA22-V1
CS1W-HCA12-V1
CS1W-CT021
CS1W-CT041
number
Unit num-
ber (rotary
switch)
Unit num-
ber (rotary
switch)
Unit num-
ber (rotary
switch)
Unit num-
ber (rotary
switch)
Unit num-
ber (rotary
switch)
Unit num-
ber (rotary
switch)
on Special
Hardware
settings
I/O Unit
Settings in
allocated
DM Area
words
Settings in
allocated
DM Area
words
Settings in
allocated
DM Area
words
Settings in
allocated
DM Area
words
Settings in
allocated
DM Area
words
Settings in
allocated
DM Area
words
CPU Unit
stored in
Settings
Settings
None
None
None
None
In flash memory:
• User program
• General-pur-
pose read-only
DM Area
• Unit functions
setting area
• Expansion
instructions
information
• Ladder library
information
None
Settings stored
in Special I/O
Unit
Refer to the operation manual for replacement procedures, and
observe the following precautions.
1) Turn OFF the power supply to all external devices connected to
2) Set the same unit number on the new Unit as was set on the Unit
3) When the new Unit has been mounted and the online replace-
Refer to the Customizable Counter Unit operation manual for
replacement procedures, and observe the following precautions.
1) Turn OFF the power supply to all external devices connected to
2) Stop Unit operation before starting the replacement procedure.
3) Set the same unit number on the new Unit as was set on the Unit
4) When the new Unit has been mounted and the online replace-
5) Use one of the following methods to transfer the same data to the
Note The version 1 (-V1) Customizable Counter Units support a
Refer to the High-speed Counter Unit operation manual for replace-
ment procedures, and observe the following precautions.
1) Turn OFF the power supply to all external devices connected to
2) Set the same unit number on the new Unit as was set on the Unit
3) When the new Unit has been mounted and the online replace-
Note If the gate open operation is being performed with bit opera-
the Unit before starting the replacement procedure.
being replaced.
ment operation has been completed for it, the settings stored in
the CPU Unit will be automatically transferred to the new Unit.
the Unit before starting the replacement procedure.
being replaced.
ment operation has been completed for it, the settings stored in
the CPU Unit will be automatically transferred to the new Unit.
flash memory in the Special I/O Unit as was in the Unit that was
replaced: a) Use the simple backup function or b) Transfer the
user program and required data from the CX-Programmer.
the Unit before starting the replacement procedure.
being replaced.
ment operation has been completed for it, the settings stored in
the CPU Unit will be automatically transferred to the new Unit.
simple backup function. If the data stored in the flash memory
in the Unit is saved to a Memory Card in advance and the
Memory Card is inserted into the CPU Unit, the Memory Card
can be used after online replacement to automatically transfer
the required data to the new Unit. (See note 1 following next
table.)
Pre-V1 versions of the Units do not support the simple backup
operation. Use the CX-Programmer to either transfer the
required data or set it again to the same settings as the Unit
being replaced. (See note 2 following next table.)
tions for the following bits, turn the bits ON after completing
online replacement so that the bits are effective: Bit 00 of
CIO n+2, Bit 00 of CIO n+5, Bit 00 of CIO n+8, and Bit 00 of
CIO n+11.