7-2
7-2-1
5. Monitor the CompoNet Network.
2. Connect to the Master Unit.
3. Upload the Network Configuration and Compare It to the Virtual Network Configuration on
4. Set the optional component parameter settings as necessary.
1. Connect online to the PLC.
the Computer
1)
2)
1)
2)
Basic Procedures
Basic Procedures
Connect the PLC to which the CompoNet Master Unit is mounted to the
computer using a serial or network connection.
For automatic online connection, select Network - Auto Online from
the menu (only supported when using a serial connection). To connect
manually, select Network - Communication Settings and set the
communications settings, and then select Network – Work Online.
In the Online Connection Information Window, right-click the CompoNet
Master Unit for the network to connect to, and select Connect.
In the Online Connection Information Window, right-click the
CompoNet Master Unit for the network to connect to, and select
Transfer [Network to PC].
Select the Network structure only option from the Transfer [Network to
PC] Dialog Box, and click the Transfer Button.
Monitor slave participation/removal status.
Monitor the Master Unit status and error history.
Check network status.
Monitor slave status.
This section describes how to use the CX-Integrator to set up and monitor network
components. The network is connected, the power supplies wired, the CompoNet
settings configured, and the serial port of the PLC to which the CompoNet Master Unit
is mounted is connected to a personal computer. The Unit can then be monitored. The
Unit parameter settings may be adjusted as required.
The basic procedures for the CX-Integrator are given below.
Step
Refer to 7-4-2 (Slave Status Tab
Page).
Refer to 7-4-2 (Unit Status Tab Page
and Error History Tab Page).
Refer to 7-4-2 (Network Status Tab
Page).
The information that can be monitored
depends on the Unit. Refer to the
manual for each Unit for details.
Refer to 7-2-2 Optional Settings.
Refer to 7-3-1 Upload the Network
Configuration to the Computer.
Refer to 7-3-1 Upload the Network
Configuration to the Computer.
Refer to 1-4-1 Direct Serial
Connections to a PLC.
Refer to 2-2-2 Procedures.
7-2 Basic Procedures
7-2-1 Basic Procedures