CS1W-CRM21 Omron, CS1W-CRM21 Datasheet - Page 308

no-image

CS1W-CRM21

Manufacturer Part Number
CS1W-CRM21
Description
CS1 CompoNet Master
Manufacturer
Omron
Datasheet

Specifications of CS1W-CRM21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
6-13 Uploading and Verifying Device Parameters
6-13-1 Uploading the Network Configuration
6-13
6-13-1
6-13-2
6-56
Network - Transfer [Network to PLC]
Using Network Configuration Window
Note
Note
Uploading the Network Configuration
Uploading Device Parameters
Component - Parameter - Upload
Uploading and Verifying Device Parameters
When the network configuration is uploaded, the parameters for each device will all be
read.
If the DeviceNet network configuration was being uploaded with the CX-Integrator
version 2.1 or higher, and the upload was cancelled or failed, the following dialog box
will be displayed the next time that the same network configuration is uploaded. This
feature allows you to upload the configuration only for the nodes where the upload
failed. (This is the DeviceNet network upload resume function.)
Uploading device parameters refers to writing the parameters from the actual network
devices to the virtual network in the CX-Integrator. Verifying device parameters refers
to comparing the parameters in the actual network devices with those in the
CX-Integrator.
This section explains how to do both of these operations.
To read the actual network configuration, use the following procedure.
1. While online, right-click the DeviceNet Unit below TargetPLC in the Online
2. Right-click the DeviceNet Unit and select Transfer [Network to PLC] from the
The following two methods can be used to read parameters from network devices.
1) Reading parameters from the Network Configuration Window
2) Reading parameters from the Edit Device Parameters Dialog Box
To upload the parameters through the Network Configuration Window, use the
following procedure.
Connection Information Window and select Connect from the popup menu.
popup menu.
Uploaded devices will be displayed in the Network Configuration Window.
When Only the nodes failed in the
previous transfer is selected for
the transfer method, only the
nodes with Failure transfer results
are transferred.