CS1W-CRM21 Omron, CS1W-CRM21 Datasheet - Page 238

no-image

CS1W-CRM21

Manufacturer Part Number
CS1W-CRM21
Description
CS1 CompoNet Master
Manufacturer
Omron
Datasheet

Specifications of CS1W-CRM21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
4-4
4-4-2
4-46
Equality Layout (Previous Method)
Equality Layout Settings
H
G
(1)
(3)
(6)
(5)
A
Area 1
(1) Area and Start Word
Area 2
(3) Area and Start Word
Area 1
Area 2
This is the previous automatic data link type where all nodes are allocated the same sizes of data
links.
Automatically Set Data Links
Controller Link Automatic Setup
(Same as (2).)
(Same as (2).)
(Same as (2).)
(Same as (4).)
(2) Size
(4) Size
1
2
3
4
1
2
3
4
(5) Participating nodes
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
B
C
D
E
F
(2)
(4)
1
2
3
1
2
3
4
4
Settings Common to All Automatic Data Link Types
Features of Equality Layout
No.
(1)
(2)
(3)
(4)
(5)
(6)
The send data sizes is the same for all nodes for each area.
No.
A
B
C
D
E
F
G
H
selected from word-access areas (e.g., DM Area).
Data link areas are allocated in ascending order of node addresses.
Data link participation can be specified for each node.
The same data link areas are shared by all nodes participating in the data links.
Area 1 is selected from the bit-access areas (e.g., CIO Area) and area 2 is
Item
Area and Start Word
for Area 1
Size of Area 1
Area and Start Word
for Area 2
Size of Area 2
Nodes
Status start word
Item
Generation
Type
Power Up
Run State
Close
Read
Write
Help
Automatic
Datalink
Type
Result
Description of function
Select Automatic. (If Manual is selected, data links will be
run using data link tables set separately.)
Select Start to automatically start data links when power is
turned ON to the PLC.
Closes the Automatic Datalink Dialog Box.
Reads the settings from the PLC.
Writes the settings to the PLC.
(If the Power Up Run State is set to Start, the data links
will start running when the settings are written to the PLC.)
Displays help.
Select the type of data links to be automatically set up
from the following.
The status is displayed when the Read or Write Button is
clicked.
Equality Layout (Previous method)
Common Type (1:N settings)
1 to 1 Type (1:N settings)
Chain Type (1:N settings)
Description of function
Set the area and the start data link word
to use for area 1.
Set the send size per node for area 1.
Set the area and the start data link word
to use for area 2.
Set the send size per node for area 2.
Set the nodes to participate in the data
links.
Set the first word to store data link status.
(If 0 words is set, the default area will be
used.)

Related parts for CS1W-CRM21