8808A/SU 120V Fluke Electronics, 8808A/SU 120V Datasheet - Page 93

USB CABLE KIT SW DMM 5.5 RES

8808A/SU 120V

Manufacturer Part Number
8808A/SU 120V
Description
USB CABLE KIT SW DMM 5.5 RES
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheet

Specifications of 8808A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1069
Updating Primary and Secondary Displays with Separate Measurements
Taking Voltage and Current Measurements Using the Dual Display
Volts DC
Volts DC
Volts DC
Volts AC
Volts AC
Volts AC
Current DC
MN MX
REL
Primary
Display
If the relative readings value of a dc voltage measurement is shown in the primary
display and the dc voltage itself is shown in the secondary display, the Meter takes a
single measurement and updates both displays with it.
If the measurement function in the primary display is different from that in the secondary
display, the Meter updates each display using a separate measurement.
Most applications of the dual display listed in Table A-2 can be performed using a single
set of test leads connected to the INPUT VZYR HI and LO terminals. However, to
measure the voltage and current of an input signal requires three leads. Be sure that the
voltage and current measurements share the same common as shown in Figure A-2. Then
simply follow the precautions you would follow if you were making normal current
measurements without a current clamp.
Volts AC
Current DC
Current AC
Current DC
Current AC
Frequency
Current AC
Actual Value
Actual Value
Secondary
Display
Table A-2. Sample Dual Display Applications
Monitor dc level and ac ripple of power supply Troubleshoot
amplifier circuits
Check power supply load regulation
Monitor UUT current draw and circuit voltages
Monitor loop current and voltage drop across transmitter
Line and load regulation tests
dc/ac or ac/dc converters
Line and load regulation tests
dc/ac or ac/dc converters
Line and load regulation tests
Transformer (magnetic circuit) saturation
Measure ac amplitude and frequency for line voltage and ac signal
analysis
Measure frequency response of an amplifier
Adjust ac motor control
Read noise in telecommunication applications
Adjust portable power generator to optimize power output
Set frequency compensation for a network
Measure ripple and dc current draw of switching power supply
Measure current dissipation in protective fuse resistors used in
power supplies
Measure ripple and noise on a line
Show the minimum or maximum value recorded and the present
measurement
Show actual measurement and the difference between this value
and the relative base.
Applications
Appendices
Applications
A
A-3