8808A/SU 120V Fluke Electronics, 8808A/SU 120V Datasheet - Page 80

USB CABLE KIT SW DMM 5.5 RES

8808A/SU 120V

Manufacturer Part Number
8808A/SU 120V
Description
USB CABLE KIT SW DMM 5.5 RES
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheet

Specifications of 8808A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1069
8808A
Users Manual
4-20
HOLDTHRESH?
MAX
MAXSET <numeric value> Meter enters MAX modifier with <numeric value> as the maximum value.
MIN
MINSET <numeric value>
MNMX
MNMXSET <numeric1,
numeric2>
MMCLR
Command
Table 4-10. Function Modifier Commands and Queries (cont.)
Meter returns Touch Hold <threshold> (1, 2, 3, or 4). See “Touch Hold
Function (HOLD)” in Chapter 3 for more information.
Meter enters MAX modifier with present reading as maximum value. If already
in MAX modifier, Meter displays maximum value. In MAX modifier,
autoranging is disabled. See “Minimum / Maximum Modifier (MIN MAX)” in
Chapter 3 for more information.
<numeric value> can be a signed integer, signed real number without
exponent, or signed real number with exponent. Autoranging is disabled. See
“Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
If <numeric value> exceeds the measurement range, an Execution Error is
generated.
Meter enters MIN modifier with present reading as minimum value. If already
in MIN modifier, Meter displays minimum value. In MIN modifier, autoranging
is disabled. See “Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for
more information.
Meter enters MIN modifier with <numeric value> as the minimum value.
<numeric value> can be a signed integer, signed real number without
exponent, or signed real number with exponent. Autoranging is disabled. See
“Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
If <numeric value> exceeds the measurement range, an Execution Error is
generated.
Meter enters MIN MAX modifier with present reading as minimum and
maximum value. If already in MIN MAX modifier, Meter displays latest MIN or
MAX value. In MIN MAX modifier, autoranging is disabled. See “Minimum /
Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
When the MIN MAX modifier is selected, you can toggle between displaying
the minimum and maximum readings without losing the minimum and
maximum values stored.
Meter enters MIN MAX modifier with <numeric1> as the maximum value and
<numeric2> as the minimum value.
<numeric1> and <numeric2> can be signed integer, signed real number
without exponent, or signed real number with exponent. Autoranging is
disabled. See “Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for
more information.
If <numeric1> or <numeric2> exceeds the measurement range, an Execution
Error is generated.
Meter exits the MN MX modifier. The stored minimum and maximum values
are lost, and the Meter returns to the ranging mode and range selected prior
to selecting MN MX modifier.
Description