ADE7569ASTZF16-RL Analog Devices Inc, ADE7569ASTZF16-RL Datasheet - Page 58

IC,Power Metering,QFP,64PIN,PLASTIC

ADE7569ASTZF16-RL

Manufacturer Part Number
ADE7569ASTZF16-RL
Description
IC,Power Metering,QFP,64PIN,PLASTIC
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADE7569ASTZF16-RL

Applications
Energy Measurement
Core Processor
8052
Program Memory Type
FLASH (16 kB)
Controller Series
ADE75xx
Ram Size
512 x 8
Interface
I²C, SPI, UART
Number Of I /o
20
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7569ASTZF16-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADE7566/ADE7569
Integration Time Under Steady Load
As mentioned in the Active Energy Calculation, the discrete
time sample period (T) for the accumulation register is 1.22 μs
(5/CLKIN). With full-scale sinusoidal signals on the analog
inputs and the VARGAIN and VARDIV registers set to 0x000,
the integration time before the reactive energy register
overflows is calculated in Equation 26.
When VARDIV is set to a value different from 0, the integration
time varies, as shown in Equation 27.
Reactive Energy Accumulation Modes
VAR Signed Accumulation Mode
The ADE7569 reactive energy default accumulation mode is a
signed accumulation based on the reactive power information.
VAR Anti-Tamper Accumulation Mode
The ADE7569 is placed in VAR anti-tamper accumulation mode
by setting the SAVARM bit in the ACCMODE Register (0x0F). In
this mode, the reactive power is accumulated depending on the
sign of the active power. When active power is positive, the
reactive power is added as it is to the reactive energy register.
When active power is negative, the reactive power is subtracted
from the reactive energy accumulator (see Figure 59). The CF
pulse also reflects this accumulation method when in this
mode. The default setting for this mode is off. Transitions in the
direction of power flow and no-load threshold are active in this
mode.
Time =
Time
0xFFFF,
0xCCCCD
=
Time
FFFF,
WDIV
FFFF
= 0
×
×
VARDIV
. 1
22
μ
s
=
409
6 .
sec
=
. 6
82
min
Rev. PrA | Page 58 of 136
(26)
(27)
REACTIVE ENERGY
REACTIVE POWER
ACTIVE POWER
APSIGN FLAG
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
NO-LOAD
NO-LOAD
NO-LOAD
NO-LOAD
Figure 59. Reactive Energy Accumulation in
Anti-Tamper Accumulation Mode
Preliminary Technical Data
INTERRUPT STATUS REGISTERS
POS
NEG
POS

Related parts for ADE7569ASTZF16-RL