WM8352GEB/V Wolfson Microelectronics, WM8352GEB/V Datasheet - Page 108

Audio CODECs Audio CODEC plus pwr management

WM8352GEB/V

Manufacturer Part Number
WM8352GEB/V
Description
Audio CODECs Audio CODEC plus pwr management
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8352GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WM8352
14.3 POWER SEQUENCING AND CONTROL
w
14.3.1
The WM8352 moves from OFF or HIBERNATE states to the ACTIVE state when a startup event
occurs. Startup events include:
The start-up events are only valid provided also that the available supply voltage, sensed on the
LINE pin, is greater than the start-up threshold set by PCCMP_ON_THR, as defined in Section 18.
Start-Up by Wall adaptor plug-in occurs when the Wall Adapter feedback pin detects a voltage
greater than 4.0V. See Section 17.1 for a description of the WALL_FB pin function.
Start-Up by USB plug-in occurs when the USB voltage rises above the LINE voltage. If USB
Suspend mode is invoked, then USB plug-in starts the WM8352 on battery power, if available. When
USB Suspend Mode is not invoked, this start-up event will lead to starting the WM8352 on USB
power, and USB 100mA trickle charging of the battery is enabled.
Note that applying a battery voltage is not a start-up event, i.e. connecting a battery pack does not
start the WM8352. The WM8352 starts up on battery power if a startup event occurs and battery
power is the only power source available, provided the battery voltage is above the startup threshold.
(The start-up threshold is set by PCCMP_ON_THR, as defined in Section 18.)
In the ACTIVE state, the host processor can read the Interrupt status fields in Register R31 in order
to determine what action initiated the start-up. These fields indicate, for example, if the start-up was
due to a reset caused by an error condition, or if the start-up was caused by a PWR_ON input, or if
the start-up was caused by an RTC alarm. The first-level interrupt WKUP_INT is triggered whenever
any of the second-level interrupt events described in Table 55 is set. See Section 24 for further
details of Interrupt.
R31 (1Fh)
Comparator
Interrupt
Status
ADDRESS
STARTUP
A trigger signal on the ON pin lasting more than 40ms. The active polarity of this input is
set by the register field ON_POL.
A trigger signal on a GPIO pin configured as /WAKEUP lasting more than 40ms. The
active polarity of this input is set by GPn_CFG for the applicable GPIO pin (see
Section 20).
A trigger signal on a GPIO pin configured as PWR_ON input lasting more than 40ms. The
active polarity of this input is set by GPn_CFG for the applicable GPIO pin (see
Section 20).
Programmed ALARM from RTC module, if enabled (see Section 22).
Wall adaptor plug-in (WALL_FB rises above 4.0V).
USB plug-in (USB pin rises above 4.0V).
BIT
6
5
4
3
WKUP_OFF_STATE_EINT
WKUP_HIB_STATE_EINT
WKUP_CONV_FAULT_EINT
WKUP_WDOG_RST_EINT
LABEL
Indicates that the chip started from the
OFF state.
(Rising Edge triggered)
Note: This bit is cleared once read.
Indicated the chip started up from the
hibernate state.
(Rising Edge triggered)
Note: This bit is cleared once read.
Indicates the wakeup was caused by a
converter fault leading to the chip being
reset.
(Rising Edge triggered)
Note: This bit is cleared once read.
Indicates the wakeup was caused by a
watchdog heartbeat being missed, and
hence the chip being reset.
(Rising Edge triggered)
Note: This bit is cleared once read.
PD, March 2010, Rev 4.2
DESCRIPTION
Production Data
108