XBP09-DPSIT-156 Digi International, XBP09-DPSIT-156 Datasheet - Page 36

MODULE XBEE PRO W/RPSMA

XBP09-DPSIT-156

Manufacturer Part Number
XBP09-DPSIT-156
Description
MODULE XBEE PRO W/RPSMA
Manufacturer
Digi International
Series
XBEE-PRO™r
Datasheets

Specifications of XBP09-DPSIT-156

Frequency
902MHz ~ 928MHz
Data Rate - Maximum
156kbps
Modulation Or Protocol
FHSS
Applications
ISM
Power - Output
17dBm (50mW)
Sensitivity
-100dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
80mA
Current - Transmitting
210mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1169
Serial Interfacing (I/O)
Serial Interfacing Commands
I/O Commands
I/O Commands
XBee‐PRO® 900 RF Modules  
AT
Command
AP
AO
BD
RO
FT
NB
SB
D7
D6
AT
Command
P0
Name and Description
API mode. Set or read the API mode of the radio. The following settings are allowed:
0 API mode is off. All UART input and output is raw data and packets are delineated
using the RO and RB parameters.
1 API mode is on. All UART input and output data is packetized in the API format,
without escape sequences.
2 API mode is on with escaped sequences inserted to allow for control characters (XON,
XOFF, escape, and the 0x7e delimiter to be passed as data.)
API Output Format. Enables different API output frames. Options include:
0 Standard Data Frames (0x90 for RF RX)
1 Explicit Addressing Data Frames (0x91 for RF RX)
Baud rate. Set or read serial interface rate (speed for data transfer between radio
modem and host). Values from 0-8 select preset standard rates. Values at 0x39 and
above select the actual baud rate. Providing the host supports it. Baud rates can go as
high as 1.875Mbps. The values from 0 to 8 are interpreted as follows:
Packetization Timeout. Set/Read number of character times of inter-character silence
required before packetization. Set (RO=0) to transmit characters as they arrive instead of
buffering them into one RF packet.
Flow Control Threshhold. Set or read flow control threshhold. De-assert CTS and/or
send XOFF when FT bytes are in the UART receive buffer. Re-assert CTS when less
than FT - 16 bytes are in the UART receive buffer.
Parity. Set or read parity settings for UART communications. The values from 0 to 4 are
interpreted as follows:
Stop Bits. Set or read number of stop bits used for UART communications.
DIO7 Configuration. Configure options for the DIO7 line of the module. Options include:
0 = Input, unmonitored
1 = CTS flow control
3 = Digital input, monitored
4 = Digital output low
5 = Digital output high
6 = RS-485 Tx enable, low TX (0V on transmit, high when idle)
7 = RS-485 Tx enable, high TX (high on transmit, 0V when idle)
DIO6 Configuration. Configure options for the DIO6 line of the module. Options include:
0 = Input, unmonitored
1 = RTS flow control
3 = Digital input, monitored
4 = Digital output low
5 = Digital output high
Name and Description
DIO10/PWM0 Configuration. Configure options for the DIO10/PWM0 line of the
module. Options include:
0 = Input, unmonitored
1 = RSSI
2 = PWM0
3 = Digital input, monitored
4 = Digital output low
5 = Digital output high
0 - 1,200bps
1 - 2,400bps
2 - 4,800bps
0 No parity
1 Even parity 4 Forced low parity
2 Odd parity
0 - 1 stop bit
3 Forced high parity
3 - 9,600bps
4 - 19,200bps
5 - 38,400bps
1 - 2 stop bits
© 2009 Digi International, Inc.
6 - 57,600bps
7 - 115,200bps
8 - 230,400bps
Parameter Range
0, 1, or 2
0, 1
0 to 8, and 0x39 to
0x1c9c38
0 - 0xFF
17 to 319
0 to 4
0 to 1
0-1, 3-7
0-1, 3-5
Parameter Range
0-5
[x character times]
Default
0
0
0x03 (9600
bps)
3
0x13F =319
0 (No parity)
0 (1 stop bit)
0
0
Default
1
     36

Related parts for XBP09-DPSIT-156