Description
IC MCU 8K FLASH 8MHZ 32-LQFP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MCHC908GR8AVFAE

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
21
Program Memory Size
7.5KB (7.5K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 6x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
32-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCHC908GR8AVFAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Clock Generator Module (CGM)
AUTO — Automatic Bandwidth Control Bit
LOCK — Lock Indicator Bit
ACQ — Acquisition Mode Bit
4.5.3 PLL Multiplier Select Register High
The PLL multiplier select register high (PMSH) contains the programming information for the high byte of
the modulo feedback divider.
MUL11–MUL8 — Multiplier Select Bits
PMSH[7:4] — Unimplemented Bits
68
This read/write bit selects automatic or manual bandwidth control. When initializing the PLL for manual
operation (AUTO = 0), clear the ACQ bit before turning on the PLL. Reset clears the AUTO bit.
When the AUTO bit is set, LOCK is a read-only bit that becomes set when the VCO clock, CGMVCLK,
is locked (running at the programmed frequency). When the AUTO bit is clear, LOCK reads as logic 0
and has no meaning. The write one function of this bit is reserved for test, so this bit must always be
written a 0. Reset clears the LOCK bit.
When the AUTO bit is set, ACQ is a read-only bit that indicates whether the PLL is in acquisition mode
or tracking mode. When the AUTO bit is clear, ACQ is a read/write bit that controls whether the PLL is
in acquisition or tracking mode.
In automatic bandwidth control mode (AUTO = 1), the last-written value from manual operation is
stored in a temporary location and is recovered when manual operation resumes. Reset clears this bit,
enabling acquisition mode.
These read/write bits control the high byte of the modulo feedback divider that selects the VCO
frequency multiplier N. (See
the multiplier select registers configures the modulo feedback divider the same as a value of $0001.
Reset initializes the registers to $0040 for a default multiply value of 64.
These bits have no function and always read as 0s.
1 = Automatic bandwidth control
0 = Manual bandwidth control
1 = VCO frequency correct or locked
0 = VCO frequency incorrect or unlocked
1 = Tracking mode
0 = Acquisition mode
Address: $0038
The multiplier select bits have built-in protection such that they cannot be
written when the PLL is on (PLLON = 1).
Reset:
Read:
Write:
Figure 4-6. PLL Multiplier Select Register High (PMSH)
Bit 7
0
0
MC68HC908GR8A • MC68HC908GR4A Data Sheet, Rev. 5
= Unimplemented
4.3.3 PLL Circuits
6
0
0
5
0
0
NOTE
and
4
0
0
4.3.6 Programming the
MUL11
3
0
MUL10
2
0
MUL9
PLL.) A value of $0000 in
1
0
Freescale Semiconductor
MUL8
Bit 0
0