Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
176-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417706F133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
13.3.9
The second alarm register (RSECAR) is an 8-bit read/write register, and an alarm register
corresponding to the BCD-coded second section counter RSECCNT of the RTC. When the ENB
bit is set to 1, a comparison with the RSECCNT value is performed. From among the
RSECAR/RMINAR/RHRAR/RWKAR/RDAYAR/RMONAR registers, the counter and alarm
register comparison is performed only on those with ENB bits set to 1, and if each of those
coincide, an RTC alarm interrupt is generated.
The range of second can be set is 00 to 59 (decimal). Errant operation will result if any other value
is set.
The ENB bit in RSECAR is initialized to 0 by a power-on reset. The remaining RSECAR fields
are not initialized by a power-on reset or manual reset, or in standby mode.
13.3.10 Minute Alarm Register (RMINAR)
The minute alarm register (RMINAR) is an 8-bit read/write register, and an alarm register
corresponding to the BCD-coded minute section counter RMINCNT of the RTC. When the ENB
bit is set to 1, a comparison with the RMINCNT value is performed. From among the
RSECAR/RMINAR/RHRAR/RWKAR/RDAYAR/RMONAR registers, the counter and alarm
register comparison is performed only on those with ENB bits set to 1, and if each of those
coincide, an RTC alarm interrupt is generated.
The range of minute can be set is 00 to 59 (decimal). Errant operation will result if any other value
is set.
The ENB bit in RMINAR is initialized by a power-on reset. The remaining RMINAR fields are
not initialized by a power-on reset or manual reset, or in standby mode.
Bit
7
6 to 4
3 to 0
Second Alarm Register (RSECAR)
Bit Name
Initial Value
0
R/W
R/W
R/W
R/W
Description
Second Alarm Enable
0: No compared
1: Compared
Setting value for 10-unit of second alarm in the
BCD-code.
The range can be set from 0 to 5 (decimal).
Setting value for 1-unit of second alarm in the
BCD-code.
The range can be set from 0 to 9 (decimal).
Rev. 5.00 May 29, 2006 page 347 of 698
Section 13 Realtime Clock (RTC)
REJ09B0146-0500

Related parts for HD6417706F133