EP9312-IB Cirrus Logic Inc, EP9312-IB Datasheet - Page 622

IC ARM920T MCU 200MHZ 352-PBGA

EP9312-IB

Manufacturer Part Number
EP9312-IB
Description
IC ARM920T MCU 200MHZ 352-PBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9312-IB

Core Processor
ARM9
Core Size
16/32-Bit
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
352-BGA
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No
Other names
598-1259

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9312-IB
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9312-IBZ
Manufacturer:
CIRRUS
Quantity:
30
Part Number:
EP9312-IBZ
Manufacturer:
HITTITE
Quantity:
1 200
Part Number:
EP9312-IBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
17
IrFlag
17-26
IrDA
EP93xx User’s Guide
31
15
Bit Descriptions:
Address:
Default:
Definition:
Bit Descriptions:
30
14
29
13
RSVD
28
12
address of all ones are broadcast frames, and are always matched regardless
of the value in the AMV. The AMV may be written at any time, allowing the
address match value to be changed during active receive operation.
RSVD:
AMV:
0x808B_008B - Read Only
0x0000_0000
IrDA Flag Register. Contains the nine read only flags which indicate the
current state of the IrDA Interface.
RSVD:
TBY:
RIF:
RSY:
EOF:
27
11
26
10
Copyright 2007 Cirrus Logic
TBY
25
9
Reserved. Unknown During Read.
Address Match Value.
Reserved. Unknown During Read.
Transmitter Busy Flag.
0 - Transmitter is idle, or disabled, or an abort is being
transmitted.
1 - Transmit logic is currently transmitting a frame.
Receiver In Frame.
0 - Receiver is in preamble/start flag or is in hunt mode.
1 - Receiver is in a frame.
Receiver Synchronized Flag.
0 - Receiver is in hunt mode.
1 - Receiver logic is synchronized within the incoming
data.
End of Frame.
0 - Current frame is not completed.
1 - The word in the receive buffer contains the last byte of
data within the frame. When the last word in the current
frame is read this bit is cleared.
RIF
24
8
RSVD
RSY
23
7
EOF
22
6
WST
21
5
WST
20
4
FRE
19
3
ROR
18
2
CRE
17
1
DS785UM1
RAB
16
0

Related parts for EP9312-IB