ATA6602-PLQW ATMEL [ATMEL Corporation], ATA6602-PLQW Datasheet - Page 54

no-image

ATA6602-PLQW

Manufacturer Part Number
ATA6602-PLQW
Description
Microcontroller with LIN Transceiver, 5V Regulator and Watchdog
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA6602-PLQW
Manufacturer:
ATMEL
Quantity:
1 727
Part Number:
ATA6602-PLQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
4.6.6
54
ATA6602/ATA6603
Calibrated Internal RC Oscillator
The calibrated internal RC Oscillator by default provides a 8.0 MHz clock. The frequency is nom-
inal value at 3V and 25°C. The device is shipped with the CKDIV8 Fuse programmed. See
“System Clock Prescaler” on page 57
clock by programming the CKSEL Fuses as shown in
no external components. During reset, hardware loads the calibration byte into the OSCCAL
Register and thereby automatically calibrates the RC Oscillator. At 3V and 25 C, this calibration
gives a frequency of 8 MHz ±1%. The tolerance of the internal RC oscillator remains better than
±10% within the whole automotive temperature and voltage ranges (2.7V to 5.5V, –40°C to
+125°C. The oscillator can be calibrated to any frequency in the range 7.3 - 8.1 MHz within ±1%
accuracy, by changing the OSCCAL register. When this Oscillator is used as the chip clock, the
Watchdog Oscillator will still be used for the Watchdog Timer and for the Reset Time-out. For
more information on the pre-programmed calibration value (see
Table 4-11.
Notes:
When this Oscillator is selected, start-up times are determined by the SUT Fuses as shown in
Table
Table 4-12.
Note:
Power Conditions
BOD enabled
Fast rising power
Slowly rising power
4-12.
1. The device is shipped with this option selected.
2. The frequency ranges are preliminary values. Actual values are TBD.
3. If 8 MHz frequency exceeds the specification of the device (depends on V
1. If the RSTDISBL fuse is programmed, this start-up time will be increased to
2.
Fuse can be programmed in order to divide the internal frequency by 8.
14CK + 4.1 ms to ensure programming mode can be entered.
The device is shipped with this option selected.
Internal Calibrated RC Oscillator Operating Modes
Start-up Times for the Internal Calibrated RC Oscillator Clock Selection
Frequency Range
7.3 - 8.1
Power-down and Power-save
Start-up Time from
(2)
(MHz)
for more details. This clock may be selected as the system
Reserved
6 CK
6 CK
6 CK
Table
4-11. If selected, it will operate with
Additional Delay from
Reset (V
“Calibration Byte” on page
14CK + 65 ms
14CK + 4.1 ms
(1)(3)
14CK
CC
CKSEL3..0
(1)
= 5.0V)
0010
(2)
CC
), the CKDIV8
4921C–AUTO–01/07
SUT1..0
00
01
10
11
301).