ATA6602-PLQW ATMEL [ATMEL Corporation], ATA6602-PLQW Datasheet - Page 252

no-image

ATA6602-PLQW

Manufacturer Part Number
ATA6602-PLQW
Description
Microcontroller with LIN Transceiver, 5V Regulator and Watchdog
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA6602-PLQW
Manufacturer:
ATMEL
Quantity:
1 727
Part Number:
ATA6602-PLQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Table 4-92.
252
Status Code
(TWSR)
Prescaler
Bits
are 0
0x90
0x98
0xA0
ATA6602/ATA6603
Status of the 2-wire Serial
Bus and 2-wire Serial
Interface Hardware
Previously addressed with
general call; data has been
received; ACK has been
returned
Previously addressed with
general call; data has been
received; NOT ACK has been
returned
A STOP condition or repeated
START condition has been
received while still addressed
as Slave
Status Codes for Slave Receiver Mode (Continued)
Read data byte or
Read data byte or
Read data byte or
Read data byte or
To/from TWDR
Read data byte
Read data byte
No action
Application Software Response
STA
X
X
0
0
1
1
0
0
1
1
STO TWINT TWEA
To TWCR
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
0
1
0
1
0
1
0
1
0
1
Next Action Taken by TWI Hardware
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”;
a START condition will be transmitted when the bus
becomes free
4921C–AUTO–01/07