C8051F351-GMR Silicon Laboratories Inc, C8051F351-GMR Datasheet - Page 136

IC 8051 MCU 8K FLASH 28MLP

C8051F351-GMR

Manufacturer Part Number
C8051F351-GMR
Description
IC 8051 MCU 8K FLASH 28MLP
Manufacturer
Silicon Laboratories Inc
Series
C8051F35xr
Datasheets

Specifications of C8051F351-GMR

Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
17
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x24b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Processor Series
C8051F3x
Core
8051
Data Bus Width
8 bit
Data Ram Size
768 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
17
Number Of Timers
4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
KSK-SL-TOOLSTICK, PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F350DK
Minimum Operating Temperature
- 40 C
On-chip Adc
24 bit, 8 Channel
On-chip Dac
8 bit, 2 Channel
For Use With
336-1083 - DEV KIT FOR F350/351/352/353
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
C8051F350/1/2/3
17.4. System Clock Selection
The internal oscillator requires little start-up time and may be selected as the system clock immediately fol-
lowing the OSCICN write that enables the internal oscillator. External crystals and ceramic resonators typ-
ically require a start-up time before they are settled and ready for use. The Crystal Valid Flag (XTLVLD in
register OSCXCN) is set to ‘1’ by hardware when the external oscillator is settled. To avoid reading a
false XTLVLD, in crystal mode software should delay at least 1 ms between enabling the external
oscillator and checking XTLVLD. RC and C modes typically require no startup time.
The CLKSL[1:0] bits in register CLKSEL select which oscillator source is used as the system clock.
CLKSL[1:0] must be set to 01b for the system clock to run from the external oscillator; however the exter-
nal oscillator may still clock certain peripherals (timers, PCA) when the internal oscillator is selected as the
system clock. The system clock may be switched on-the-fly between the internal oscillator, external oscilla-
tor, and Clock Multiplier so long as the selected clock source is enabled and has settled.
Table 17.1. Oscillator Electrical Characteristics
–40 to +85 °C unless otherwise specified.
136
Internal Oscillator Frequency
Internal Oscillator Supply
Current (from V
Bits7–2: Unused. Read = 000000b; Write = don’t care.
Bits1–0: CLKSL1–0: System Clock Select
Bit7
R
Parameter
These bits select the system clock source.
DD
Bit6
R
)
CLKSL
00
01
10
11
SFR Definition 17.5. CLKSEL: Clock Select
Bit5
R
Bit4
R
Internal Oscillator (as determined by the
Reset Frequency
OSCICN.7 = 1
Conditions
IFCN bits in register OSCICN)
Rev. 1.1
Bit3
External Oscillator
R
Selected Clock
Clock Multiplier
RESERVED
Bit2
R
Min
24
R/W
Bit1
CLKSL
24.5
Typ
450
SFR Address:
R/W
Bit0
Max
25
0xA9
00000000
Reset Value
Units
MHz
µA